A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Rapid and convenient determination of α-dicarbonyl compounds via streamlined simultaneous derivatization and extraction coupled with liquid chromatography-fluorescence detection. | LitMetric

AI Article Synopsis

  • *A new one-pot method combines derivatization and magnetic solid-phase extraction to simplify the detection of α-DCs.
  • *This method was effective in analyzing α-DCs in various beverages, with detection limits ranging from 0.4 to 3.5 nM.

Article Abstract

α-Dicarbonyl compounds (α-DCs), formed during food heating and storage, are crucial for assessing food safety and quality. However, the low concentration, high reactivity, and absence of chromophores of α-DCs make their detection challenging, often requiring complex derivatization and extraction. This study developed a one-pot method for α-DCs that combines derivatization and magnetic solid-phase extraction. By mixing the sample, 2,3-diaminonaphthalene, and FeO/MWCNTs-OH in a vial, simultaneous derivatization and extraction are achieved. Derivatization converts α-DCs into hydrophobic products, facilitating their adsorption and enabling sensitive liquid chromatography-fluorescence detection. The introduction of the magnetic adsorbent allows phase separation to be easily achieved using an external magnet, simplifying and speeding up the process. The detection limits for six α-DCs (glyoxal, methylglyoxal, diacetyl, 2,3-pentanedione, D-glucosone, and 3-deoxyglucosone) were determined to be in the range of 0.4-3.5 nM. This rapid and convenient analytical approach was successfully applied to analyze α-DCs in juices, coffees, and tea beverages.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11471521PMC
http://dx.doi.org/10.1016/j.fochx.2024.101858DOI Listing

Publication Analysis

Top Keywords

derivatization extraction
12
rapid convenient
8
α-dicarbonyl compounds
8
simultaneous derivatization
8
liquid chromatography-fluorescence
8
chromatography-fluorescence detection
8
α-dcs
6
derivatization
5
convenient determination
4
determination α-dicarbonyl
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!