Purpose: This study aimed to assess the refractive outcomes following the combined intervention of silicon oil (SO) removal and ciliary sulcus intraocular lens (IOL) implantation in aphakic eyes after phacovitrectomy.
Methods: A retrospective examination of medical records from patients who underwent a combined procedure of SO removal and ciliary sulcus IOL implantation from 2019 to 2022 was performed. The primary outcomes of interest included uncorrected distance visual acuity (UDVA), predictive error (PE) and mean absolute predictive error (MAE). Subgroup analyses were performed to compare outcomes between patients with and without intraoperative posterior capsulotomy.
Results: The cohort comprised 40 eyes from 40 patients, with a mean duration of SO tamponade of 5.17 ± 1.48 months. A significant improvement in UDVA was observed from 1.58 ± 0.31 logMAR to 0.99 ± 0.31 logMAR one month postoperatively (< 0.01). The PE was -0.73 ± 0.86 diopters (D), and the MAE was 0.90 ± 0.67 D, with 37.50% and 57.50% of cases achieving PE within ±0.5 D and ±1.0 D, respectively. No significant differences in UDVA, PE, or MAE were found between the capsulotomy and non-capsulotomy subgroups (all > 0.05). However, a lower proportion of eyes in the capsulotomy group achieved PE within ±1.0 D compared to the non-capsulotomy group one month postoperatively (38.90% vs. 72.70%, = 0.03).
Conclusions: The combined procedure of SO removal and sulcus IOL implantation resulted in a mild myopic shift in postoperative refraction. Intraoperative posterior capsulotomy seems to increase the lability of postoperative refractive outcomes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/11206721241287255 | DOI Listing |
Int Ophthalmol
January 2025
Department of Ophthalmology, Peking University Third Hospital, No 49 Huayuan North Road, Haidian District, Beijing, 100191, China.
Purpose: To evaluate clinical outcomes and visual quality 12 months after small incision lenticule extraction (SMILE) for correction of myopia with or without astigmatism in patients during the incipient phase of presbyopia.
Setting: Peking University Third Hospital, Beijing, China.
Design: Retrospective observation study.
J Res Nurs
January 2025
Ophthalmologist, Department of Ophthalmology, Westmead Hospital, Westmead, NSW, Australia.
Background: COVID-related clinic shutdowns mandated the use of a day 1 telephone follow-up the day after routine cataract surgery rather than clinic attendance. We investigated to see if this is a safe alternative to standard care.
Methods: Ninety-nine patients who underwent a routine cataract extraction between 22 April 2020 and 19 August 2020 at our Hospital were included in this audit.
Conventional refractive microscope objective lenses have limited applicability to a range of imaging modalities due to the dispersive nature of their optical elements. Designing a conventional refractive microscope objective that provides well-corrected imaging over a broad spectral range can be challenging, if not impossible. In contrast, reflective optics are inherently achromatic, so a system composed entirely of reflective elements is free from chromatic aberrations and, as a result, can image over an ultra-wide spectral range with perfect color correction.
View Article and Find Full Text PDFJ Ophthalmol
January 2025
Optics and Optometry Department, Universidad Complutense de Madrid, Madrid, Spain.
To analyze the refractive accuracy of a novel swept-source optical coherence biometer (SS-OCT), that uses individual refractive indices to measure axial length, in short and long eyes implanted with monofocal intraocular lenses (IOLs). This retrospective comparative study considered eyes with short axial length (AL) (< 22.5 mm) or long AL (> 26 mm) bilaterally implanted with the Acrysof IQ monofocal IOL.
View Article and Find Full Text PDFSci Rep
January 2025
School of Physics, Xidian University, Xi'an, 710071, Shaanxi, China.
The impact of different turbulence on beams can be seen as optical distortions caused by refractive index fluctuations around vortices in turbulence. Therefore, from the perspective of transmission effects, the transmission outcomes of beam in different turbulences can be mutually equivalent. Since the mechanisms of beam propagation in compressible turbulence are not yet fully understood and the relevant theories are not well-established, a preliminary analysis of beam transmission in compressible turbulence is necessary.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!