Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Studies have found that matrix metalloproteinase-9 (MMP-9) and interleukin-6 (IL-6) play an important role in tumorigenesis. In order to detect MMP-9 and IL-6 concentrations with high sensitivity and specificity, an efficient microfluidic-SERS sensing system was prepared based on surface-enhanced Raman scattering (SERS). The aptamer recognition-release mechanism and the dual signal amplification strategy were applied in the sensing system. The sensor system was developed using two kinds of nanomaterials with excellent SERS properties, namely gold-coated iron tetroxide particles (FeO@AuNPs) and gold nanocages (AuNCs). In addition, FeO@AuNPs also has magnetic adsorption properties. In the sensing system, single-stranded DNA1 (ssDNA1) and aptamer were modified on FeO@AuNPs. Single-stranded DNA2 (ssDNA2) and Raman tags were modified on AuNCs. When the target was present, the aptamer bound to the target and detached from the FeO@AuNPs, and ssDNA2 bound to the exposed ssDNA1. At this time, the FeO@AuNPs@AuNCs@SERS tag complex was formed, and the SERS signal was enhanced for the first time. Under the action of an external magnet on the microfluidic chip, the complex was magnetized and enriched. The SERS signal was enhanced for the second time. Due to the high affinity between the aptamer and the target object, the sensing system has a strong specificity. The double amplification of the SERS signal gave the system excellent sensitivity. The limit of detection (LOD) relative to MMP-9 and IL-6 were as low as 0.178 pg/mL and 0.165 pg/mL, respectively. The microfluidic-SERS sensing system has a feasible prospect in the early screening of gastric cancer.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00604-024-06760-z | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!