Background: Biomarker analyses are an integral part of cancer research. Despite the intense efforts to identify and characterize biomarkers in patients with cancer, little is known regarding the natural variation of biomarkers in healthy populations. Here we conducted a clinical study to evaluate the natural variability of biomarkers over time in healthy participants.
Methods: The angiome multiplex array, a panel of 25 circulating protein biomarkers, was assessed in 28 healthy participants across eight timepoints over the span of 60 days. We utilized the intraclass correlation coefficient (ICC) to quantify the reliability of the biomarkers. Adjusted ICC values were calculated under the framework of a linear mixed-effects model, taking into consideration age, sex, body mass index, fasting status, and sampling factors.
Results: ICC was calculated to determine the reliability of each biomarker. Hepatocyte growth factor was the most stable marker (ICC = 0.973), while platelet-derived growth factor (PDGF)-BB was the most variable marker (ICC = 0.167). In total, ICC analyses revealed that 22 out of 25 measured biomarkers display good (≥0.4) to excellent (>0.75) ICC values. Three markers (PDGF-BB, TGFβ1, PDGF-AA) had ICC values <0.4. Greater age was associated with higher IL6 (P = 0.0114). Higher body mass index was associated with higher levels of IL6 (P = 0.0003) and VEGF-R3 (P = 0.0045).
Conclusions: Of the 25 protein biomarkers measured over this short time period, 22 markers were found to have good or excellent ICC values, providing additional validation for this biomarker assay.
Impact: These data further support the validation of the angiome biomarker assay and its application as an integrated biomarker in clinical trial testing.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11717622 | PMC |
http://dx.doi.org/10.1158/1055-9965.EPI-24-0644 | DOI Listing |
Sensors (Basel)
January 2025
Institute of Human Movement Science, Sport and Health, University of Graz, 8010 Graz, Austria.
Unlabelled: In recent years, the EnodePro device has been one of the most frequently used velocity sensors to track the bar velocity in resistance training, with the aim of providing load-velocity profiles. However, recent articles highlight a lack of reliability and validity in the estimated maximal strength, which can cause a serious health risk due to the overestimation of the bar velocity. With this study, we aimed to investigate whether imprecision in the measurement could explain the variance in this measurement error.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Obstetrics and Gynaecology, Croydon University Hospital, Croydon CR7 7YE, UK.
The aim of this study is to validate a uniform method for measuring perineal descent which can be used for different imaging methods, to establish cut-off values for this measurement, and to assess diagnostic test accuracy (DTA) of imaging techniques using these cut-off values. Secondly, the study aims to correlate perineal descent to symptoms, signs and imaging findings in women with obstructed defaecation syndrome (ODS) to assess its clinical relevance. Cross-sectional study of 131 women with symptoms of ODS.
View Article and Find Full Text PDFLife (Basel)
January 2025
Department of Coaching Education, Marmara University Faculty of Sport Sciences, 34815 Istanbul, Turkey.
This study evaluated the validity and reliability of the TecnoBody D-Wall system in assessing joint range of motion (ROM) during overhead squat movements in healthy individuals, using Kinovea as a reference tool for data comparison. A total of 29 participants (16 males, 13 females) with a mean age of 28.41 ± 6.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedic Surgery, The Keck School of Medicine of USC, Los Angeles, CA 90033, USA.
: Measuring joint range of motion (ROM) is essential for diagnosing and treating musculoskeletal diseases. However, most clinical measurements are conducted using conventional devices, and their reliability may significantly depend on the tester. This study implemented an RGB-D (red/green/blue-depth) sensor-based artificial intelligence (AI) device to measure joint ROM and compared its reliability with that of a universal goniometer (UG).
View Article and Find Full Text PDFDiagnostics (Basel)
January 2025
Clinic of Diagnostic and Interventional Radiology, Marburg University Hospital, Philipps-University Marburg, Baldingerstrasse, 35043 Marburg, Germany.
Hypoxic-ischemic brain injury (HIBI) is a feared complication post-cardiac arrest (CA). The timing of brain imaging remains a topic of ongoing debate. Early computed tomography (CT) scans can reveal acute intracranial pathologies but may have limited predictive value due to delayed manifestation of HIBI-related changes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!