A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Swellable Biopolymer Composite Microneedle Patch for Pain-Free Collection of Interstitial Fluid to Analyze Multiple Biomolecules. | LitMetric

Sampling of interstitial fluid (ISF) using microneedle (MN) patch offers a pain-free minimally invasive alternative to syringe needle-based blood sample collection. However, there is a challenge in the development of MN patch that provides swelling behavior with sufficient mechanical strength for skin penetration. Here, we report fabrication of MN patch made of biopolymer composite containing iota-carrageenan, gelatin, and polyethylene glycol. Calcium chloride was used as a crosslinker to improve mechanical strength. MN patch was characterized for integrity, swelling behavior, mechanical strength, aspiration of fluid from agarose gel, and the excised porcine ear skin. An array of 361 MNs was able to aspirate 36 ± 5 and 14 ± 1 μL fluid after application in agarose gel matrix and the ex vivo porcine skin model, respectively. MN patch applied in vivo rat model for 30 min resulted in the collection of ISF containing 267 ± 128 mg/dL, 24 ± 13 mg/dL, and 0.6 ± 0.4 mIU/mL of glucose, uric acid and thyroid stimulating hormone (TSH), respectively. The concentration of glucose, uric acid, and TSH in rat blood was found to be 199 ± 47 mg/dL, 8.4 ± 6 mg/dL, and 1.1 ± 0.6 mIU/mL at the same time. Furthermore, MN patch applied on the forearm of 10 healthy human volunteers for 30 min was able to aspirate 32 ± 14 μL of ISF. The concentration of glucose, uric acid, and TSH determined from ISF samples of human volunteers was 64 ± 25 mg/dL, 4.2 ± 4.1 mg/dL, and 0.16 ± 0.08 mIU/mL, respectively. The visual analogue scale (VAS) pain score after MN application was lower compared with hypodermic syringe needle insertion. Taken together, biopolymer composite-based swellable MN patch can be developed for collection of ISF for simultaneous determination of multiple biomolecules in a minimally invasive manner.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.a.37809DOI Listing

Publication Analysis

Top Keywords

mechanical strength
12
glucose uric
12
uric acid
12
biopolymer composite
8
patch
8
microneedle patch
8
interstitial fluid
8
multiple biomolecules
8
minimally invasive
8
swelling behavior
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!