Objective: The aim of the study was to describe long-term outcomes and report post-retrieval implant analysis following cementless total knee replacement (TKR) in a dog.
Animal: A seven-year-old, male neutered, Labrador retriever.
Methods: The dog presented for evaluation of chronic left pelvic limb lameness. Orthopedic examination identified bilateral cranial drawer and medial buttress. Radiographs revealed severe bilateral osteoarthritis with moderate joint effusion/synovial hypertrophy. Given the end-stage osteoarthritis, TKR was considered more appropriate than tibial plateau leveling osteotomy (TPLO). The dog underwent a left cementless TKR.
Results: Immediate postoperative radiographs showed appropriate implant positioning. Moderate left pelvic limb lameness with full, pain free and stable stifle range of motion (ROM) was documented at 2 weeks. Increased left hindlimb weight-bearing with a peak vertical force of 70% bodyweight (BW) versus 50% BW on the contralateral leg was reported at 6 weeks. Radiographs showed good implant osseointegration. Left stifle ROM was 50°/170°, a 30° increase compared to preoperative values. Additional rechecks at 14 and 30 weeks showed gradual improvement in stifle ROM and weight-bearing. The dog was euthanized 6 years after surgery for reasons unrelated to TKR. Radiographs demonstrated static implant position without signs of osteolysis and gross examination revealed mild polyethylene wear on the caudal aspects of the tibial insert. Histological evaluation of the implant-bone interface showed extensive and robust osseointegration.
Conclusion: This case demonstrates that cementless TKR can be associated with excellent clinical function over the course of at least 6 years and suggests that early surgical intervention could be considered.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/vsu.14175 | DOI Listing |
BMC Musculoskelet Disord
January 2025
Department of Joint Surgery, The Second Hospital of Jilin University, Changchun, 130,000, Jilin Province, China.
Objectives: Tuberculosis of the hip joint is a common form of bone tuberculosis that can cause severe joint destruction and affect quality of life. Total hip arthroplasty (THA) is an important way to treat hip joint-related diseases. In recent years, THA has been applied to treat tuberculosis of the hip joint and has achieved certain results.
View Article and Find Full Text PDFJ Exp Orthop
January 2025
Department of Orthopaedic Surgery and Traumatology Città della Salute e della Scienza Turin Italy.
Purpose: This systematic review and meta-analysis aimed to compare the clinical and radiological outcomes of patients undergoing revision total knee arthroplasty (rTKA) using uncemented press-fit stems (hybrid fixation) versus cemented stems (cemented fixation). It is also examined whether cemented fixation offers any superiority over hybrid fixation regarding implant survival, clinical function, imaging analysis and complication rates.
Methods: Following the PRISMA guidelines, a systematic review and meta-analysis were conducted on five databases (Pubmed, Scopus, Embase, Medline and Cochrane).
J Clin Med
December 2024
Department of Orthopedic Surgery, Ordensklinikum Linz Barmherzige Schwestern, Vinzenzgruppe Center of Orthopedic Excellence, Teaching Hospital of the Paracelsus Medical University, 5020 Salzburg, Austria.
Short-stem total hip arthroplasty (THA) has gained popularity due to its bone-sparing technique, but its outcomes in patients with obesity remain uncertain. The aim of this study was to investigate the impact of obesity on postoperative subsidence and clinical outcomes after short-stem THA. A retrospective cohort study with a minimum follow-up of 24 months was conducted on 163 patients who underwent short-stem THA with a collarless, triple-tapered, cementless stem achieving fixation in the metaphyseal region.
View Article and Find Full Text PDFJ Knee Surg
January 2025
Orthopaedic Surgery, Mayo Clinic, Rochester, United States.
Introduction: Historically, cementless patellar implants were fraught with issues of fixation and polyethylene wear. However, contemporary cementless patellar implants incorporate modern technologies for implant design and offer the potential for improved biological fixation and longevity. As such, an evaluation of the performance of modern cementless patellae is needed.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
January 2025
Department of Orthopedic Surgery, Auckland City Hospital, Grafton, Auckland, New Zealand.
Hypothesis And Background: As the incidence of reverse total shoulder arthroplasty (RTSA) continues to rise, better understanding of the long-term risks and complications is necessary to determine the best choice of implant. The majority (75%) of RTSA performed in New Zealand use either SMR (Systema Multiplana Randelli, Lima-LTO, Italy) or Delta Xtend (DePuy Synthes, USA). The aim of this registry-based study was to compare implant survival, risk of revision and reasons for revision between the two most frequently used RTSA prostheses: SMR and Delta Xtend.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!