AI Article Synopsis

  • The study focused on identifying risk factors for lung parenchyma hemorrhage and hemoptysis in patients undergoing microwave ablation for stage I non-small cell lung cancer (NSCLC).
  • A total of 417 patients were analyzed, with data from two medical centers; univariable and multivariable logistic analyses were performed to find significant risk factors.
  • Key risk factors identified include focal blood supplies, proximity of vessels larger than 2 mm, and traversing vessels, which increased the likelihood of hemorrhage and hemoptysis during the procedure.

Article Abstract

Objectives: This study aimed to identify the risk factors for lung parenchyma hemorrhage and hemoptysis during computed tomography-guided microwave ablation (MWA) in patients with stage I non-small cell lung cancer (NSCLC).

Methods: A total of 417 patients from two medical centers were included, of whom 353 were from center 1 and 64 were from center 2. The risk factors for lung parenchyma hemorrhage and hemoptysis were selected by univariable and multivariable logistic analyses in the center 1 dataset. The selected risk factors were validated in the center 2 dataset.

Results: The risk factors for lung parenchyma hemorrhage during MWA were focal blood supplies (odds ratio [OR], 2.602; 95% confidence interval [CI], 1.609-4.210; p < 0.001), near vessels larger than 2 mm (OR, 4.145; 95% CI, 1.963-8.755; p < 0.001), and traversing vessels in the track of ablation (OR, 2.961; 95% CI, 1.492-5.874; p = 0.002). The risk factors for hemoptysis were lung parenchyma hemorrhage (OR, 34.165; 95% CI, 12.255-95.247; p < 0.001), needle track traversing the lung parenchyma by >25 mm (OR, 4.494; 95% CI, 1.833-11.018; p = 0.001), and traversing vessels in the track of ablation (OR, 5.402; 95% CI, 2.269-12.865; p < 0.001).

Conclusions: Focal blood supplies, near vessels larger than 2 mm, and traversing vessels in the track of ablation were independent risk factors for lung parenchyma hemorrhage during MWA. Lung parenchyma hemorrhage, needle track traversing the lung parenchyma by >25 mm, and traversing vessels in the track of ablation were independent risk factors for hemoptysis during MWA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11586133PMC
http://dx.doi.org/10.1111/1759-7714.15466DOI Listing

Publication Analysis

Top Keywords

risk factors
20
factors lung
16
lung parenchyma
16
parenchyma hemorrhage
16
hemorrhage hemoptysis
12
hemoptysis computed
8
computed tomography-guided
8
tomography-guided microwave
8
microwave ablation
8
patients stage
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!