AI Article Synopsis

  • A new method using inductively coupled plasma mass spectrometry (ICP-MS) was developed to simultaneously measure 22 elements in whole blood, including metals like iron and lead.
  • The method involved optimizing various analysis conditions, diluting blood samples with specific chemicals, and centrifuging them before measurement.
  • Results showed strong linear relationships for element detection, with limits of detection and good precision, making it a quick and efficient option for clinical testing of multiple blood elements.

Article Abstract

To establish a method for the simultaneous determination of 22 elements, including beryllium, vanadium, chromium, manganese, iron, calcium, magnesium, barium, cobalt, cadmium, copper, zinc, arsenic, selenium, titanium, strontium, nickel, molybdenum, tin, antimony, thallium and lead, in whole blood by inductively coupled plasma mass spectrometry (ICP-MS) . In September 2023, the analysis conditions were determined by optimizing the detection mode of the instrument, the pretreatment mode and the dilution factor of the samples, etc. Whole blood samples were diluted with a mixture of 0.1% nitric acid and 0.05% triton X-100, and centrifuged at 2000 r/min by high-speed centrifuge for 2 min. The supernatant was taken into inductively coupled plasma mass spectrometer to determine the content of 22 elements, and the detection limit and precision of the method were analyzed. The 22 elements had a good linear relationship in their respective measurement ranges (=0.9991-0.9999), the detection limit ranged from 0.003 μg/L to 0.012 mg/L. The intra-batch precision ranged from 0.5% to 7.2%, the inter-batch precision ranged from 0.4% to 9.4%, and the average recoveries ranged from 80.6% to 114.9%. ICP-MS method has a good effect on the determination of 22 elements in whole blood. The method is fast and simple, and can be used for clinical detection of multiple elements in whole blood.

Download full-text PDF

Source
http://dx.doi.org/10.3760/cma.j.cn121094-20240208-00055DOI Listing

Publication Analysis

Top Keywords

elements blood
12
inductively coupled
12
coupled plasma
12
plasma mass
12
blood inductively
8
determination elements
8
detection limit
8
precision ranged
8
blood
5
elements
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!