A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparing Multipin Clamps With Outriggers With Standard Clamps for Lower Extremity Periarticular External Fixation: Similar Radiographic and Clinical Outcomes. | LitMetric

Comparing Multipin Clamps With Outriggers With Standard Clamps for Lower Extremity Periarticular External Fixation: Similar Radiographic and Clinical Outcomes.

J Am Acad Orthop Surg Glob Res Rev

From the Department of Orthopaedic Surgery, University of California Davis (Dr. Tse, Dr. Saade, Dr. Ikwuezunma, Dr. Simister, Dr. Saiz, Dr. Fitzpatrick, Dr. Soles, Dr. Lee, and Dr. Campbell); and the University of California Davis School of Medicine, Sacramento, CA (Mr. Walters).

Published: October 2024

AI Article Synopsis

  • The study investigates the effectiveness and costs of two types of external fixator clamps—standard and multipin—used for treating high-energy tibia fractures while minimizing complications.
  • A review of 100 patients treated from 2014 to 2023 showed no significant differences in clinical outcomes or radiographic alignment between the two types of external fixators, despite the multipin clamps being more expensive.
  • The findings suggest that the choice of clamp may not impact treatment results, leading to considerations for cost-effectiveness in clinical practice.

Article Abstract

Introduction: Staged treatment of high-energy periarticular tibia fractures involves temporization with closed reduction and external fixation, aiming to provide early reduction and stabilization while mitigating soft-tissue complications. Various external fixator configurations exist, including those that use a "multipin" clamp capable of holding multiple pins but limiting pin placement to a single plane. The purpose of this study was to compare clinical and radiographic outcomes and associated costs of standard and multipin outrigger clamp constructs in tibial plateau and pilon fractures treated with temporary external fixation. We hypothesized that use of the multipin clamp may be associated with poorly aligned reductions and increased complication rates.

Methods: A retrospective review of 100 patients with periarticular tibial plateau (AO/OTA: 41B/C) or pilon (43B/C) fracture at a Level 1 trauma center from 2014 to 2023 was conducted. Patient, injury, and complication characteristics were collected. Patients were categorized based on the external fixator clamp used: multipin (MP) or standard (S). Clinical outcomes and complication rates were assessed. Radiographic alignment was evaluated by the change in anterior and lateral distal tibial angles, and sagittal plane translation for pilon fractures, and medial and posterior proximal tibial angles for plateau fractures.

Results: 70 patients underwent standard (25 pilon, 45 plateau) and 30 multipin (10 pilon, 20 plateau) external fixation. MP and S groups showed no notable differences in demographics or injury characteristics. Both groups demonstrated comparable complication rates and radiological alignment outcomes, with no notable differences observed. MP constructs were more costly than standard systems.

Conclusion: In this retrospective study of 100 patients, there was no difference in radiographic or clinical outcomes between the standard frame and multipin frame groups. Typical costs for the multipin frame constructs were $635 to $1249 more than the standard frame constructs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11473059PMC
http://dx.doi.org/10.5435/JAAOSGlobal-D-24-00279DOI Listing

Publication Analysis

Top Keywords

external fixation
16
clinical outcomes
12
radiographic clinical
8
external fixator
8
tibial plateau
8
pilon fractures
8
100 patients
8
complication rates
8
tibial angles
8
pilon plateau
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!