Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The present study compared respiratory parameters between the two methods of airway establishment, ETT and LMA, for patients scheduled for orthopedic surgery with general anesthesia.
Methods: This randomized double-blinded clinical trial was conducted on patients scheduled for elective orthopedic surgery under general anesthesia, in Bandar Abbas, Iran, from January 2021 to December 2021. Using a random allocation table, the study participants were randomly divided into two groups, to employ either ETT (n=48) or LMA insertion (n=48). The study's ultimate goal was to assess the respiratory parameters in 1, 3, 5, 10, and 15 minutes following intubation.
Results: At all-time points, the average of peak airway pressure (P peak) and P plateau parameters in the ETT group was much higher than the EMA group (<0.001 in all comparisons). The value of dynamic lung compliance in the LMA group was significantly higher than the ETT group in all considered time periods (<0.001 in all comparisons). The upward trend in the value of this index was significant only in the LMA group (=0.030). There were no significant differences in arterial oxygen saturation and end-tidal carbon dioxide levels between the two groups (>0.05).
Conclusion: In terms of arterial oxygen saturation stability and at the same time providing respiratory dynamic compliance, the LMA device outperformed the ETT.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11462110 | PMC |
http://dx.doi.org/10.30476/beat.2024.102372.1509 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!