P magnetic resonance spectroscopy (MRS) can spectrally resolve metabolites involved in phospholipid metabolism whose levels are altered in many cancers. Ultra-high field facilitates the detection of phosphomonoesters (PMEs) and phosphodiesters (PDEs) with increased SNR and spectral resolution. Utilizing multi-echo MR spectroscopic imaging (MRSI) further enhances SNR and enables T information estimation per metabolite. To address the specific absorption rate (SAR) challenges associated with high-power demanding adiabatic or composite block pulses in multi-echo phosphorus imaging, we present a dual-band refocusing RF pulse designed for operation at B amplitudes of 14.8 μT which holds potential for integration into multi-echo sequences. Phantom and in vivo experiments conducted in the brain at 7 Tesla validated the effectiveness of this low-power dual-band RF pulse. Furthermore, we implemented the dual-band RF pulse into a multi-echo MRSI sequence where it offered the potential to increase the number of echo pulses within the same acquisition time compared to high-power adiabatic implementation, demonstrating its feasibility and practicality.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11602691PMC
http://dx.doi.org/10.1002/nbm.5273DOI Listing

Publication Analysis

Top Keywords

multi-echo mrsi
8
dual-band refocusing
8
dual-band pulse
8
multi-echo
5
mrsi low
4
dual-band
4
low dual-band
4
refocusing pulses
4
pulses magnetic
4
magnetic resonance
4

Similar Publications

P magnetic resonance spectroscopy (MRS) can spectrally resolve metabolites involved in phospholipid metabolism whose levels are altered in many cancers. Ultra-high field facilitates the detection of phosphomonoesters (PMEs) and phosphodiesters (PDEs) with increased SNR and spectral resolution. Utilizing multi-echo MR spectroscopic imaging (MRSI) further enhances SNR and enables T information estimation per metabolite.

View Article and Find Full Text PDF

Whole brain ionic and metabolic imaging has potential as a powerful tool for the characterization of brain diseases. We combined sodium MRI ( Na MRI) and H-MR Spectroscopic Imaging ( H-MRSI), assessing changes within epileptogenic networks in comparison with electrophysiologically normal networks as defined by stereotactic EEG (SEEG) recordings analysis. We applied a multi-echo density adapted 3D projection reconstruction pulse sequence at 7 T ( Na-MRI) and a 3D echo-planar spectroscopic imaging sequence at 3 T ( H-MRSI) in 19 patients suffering from drug-resistant focal epilepsy who underwent presurgical SEEG.

View Article and Find Full Text PDF

Background: Absolute quantification of metabolites in MR spectroscopic imaging (MRSI) requires a stable reference signal of known concentration. The Electronic REference To access In vivo Concentrations (ERETIC) has shown great promise but has not been applied in patients and 3D MRSI. ERETIC hardware has not been integrated with receive arrays due to technical challenges, such as coil combination and unwanted coupling between multiple ERETIC and receive channels, for which we developed mitigation strategies.

View Article and Find Full Text PDF

Comparison of selective excitation and multi-echo chemical shift encoding for imaging of hyperpolarized [1-C]pyruvate.

J Magn Reson

April 2021

Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, United States; Medical Physics Graduate Program, The University of Texas MD Anderson Cancer Center, UTHealth Graduate School of Biomedical Sciences, Houston, TX, United States. Electronic address:

Imaging methods for hyperpolarized (HP) C agents must sample the evolution of signal from multiple agents with distinct chemical shifts within a very brief timeframe (typically < 1 min), which is challenging using conventional imaging methods. In this work, we compare two of the most commonly used HP spectroscopic imaging methods, spectral-spatial selective excitation and multi-echo chemical shift encoding (CSE, also referred to as IDEAL), for a typical preclinical HP [1-C]pyruvate imaging scan at 7 T. Both spectroscopic encoding techniques were implemented and validated in HP experiments imaging enzyme phantoms and the murine kidney.

View Article and Find Full Text PDF

Phosphorus ( P) MRSI provides opportunities to monitor potential biomarkers. However, current applications of P MRS are generally restricted to relatively small volumes as small coils are used. Conventional surface coils require high energy adiabatic RF pulses to achieve flip angle homogeneity, leading to high specific absorption rates (SARs), and occupy space within the MRI bore.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!