A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ratiometric fluorescence probe based on boric acid-modified carbon dots and alizarin red for sensitive and rapid detection of glyphosate. | LitMetric

Ratiometric fluorescence probe based on boric acid-modified carbon dots and alizarin red for sensitive and rapid detection of glyphosate.

Mikrochim Acta

Guangzhou Key Laboratory of Analytical Chemistry for Biomedicine, School of Chemistry, South China Normal University, Guangzhou, 510006, Guangdong, China.

Published: October 2024

By combining boric acid-modified carbon dots (p-CDs) and alizarin red (ARS), a double emission probe p-CDs@ARS with fluorescence at 410 nm and 600 nm is designed for the detection of glyphosate. When Cu is added, it binds with ARS to cause ARS release from p-CDs@ARS, which decreases the fluorescence at 600 nm. However, in the presence of glyphosate, glyphosate competes to the binding of Cu, releasing ARS to bind with p-CDs again. Therefore, the fluorescence of 600 nm recovers. Based on this, the fluorescence of 410 nm and 600 nm act as the reference and response signal, respectively, achieving the ratiometric fluorescence detection of glyphosate. The linear range of glyphosate detection is 0.5-50 µM with a limit of detection at 0.37 µM which is well below the maximum residue limit for glyphosate in food. When the probe is used to detect the glyphosate residue in Pearl River water and cucumber, the detection results are well consistent with those detected by HPLC. The established method based on p-CDs@ARS has the advantages that the assembly of ratiometric fluorescence probe is simple, and the detection speed is fast. Additionally, a typical INHIBIT logical system has been successfully constructed based on glyphosate, Cu, and the fluorescence signal of p-CDs@ARS.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-024-06748-9DOI Listing

Publication Analysis

Top Keywords

ratiometric fluorescence
12
detection glyphosate
12
glyphosate
9
fluorescence probe
8
boric acid-modified
8
acid-modified carbon
8
carbon dots
8
alizarin red
8
fluorescence 410 nm
8
410 nm 600 nm
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!