A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diagnostic Accuracy of 18 F-FES PET/CT for the Detection of Recurrent and Metastatic Breast Cancer. | LitMetric

AI Article Synopsis

  • The study evaluated the effectiveness of 18F-FES PET/CT imaging in detecting distant metastasis or recurrence in patients with estrogen receptor-positive (ER-positive) breast cancer.
  • It analyzed data from 162 patients and found that 18F-FES PET/CT had a high sensitivity (95%) and specificity (89%) for diagnosing these conditions, outperforming standard imaging methods.
  • The researchers concluded that 18F-FES PET/CT is a valuable tool for accurately diagnosing ER-positive breast cancer patients who may have metastasis or recurrence.

Article Abstract

Purpose: To evaluate the diagnostic value of 16α- 18 F-fluoro-17β-fluoroestradiol ( 18 F-FES) PET/CT for distant metastasis or recurrence in patients with estrogen receptor (ER)-positive breast cancer.

Methods: Patients with ER-positive breast cancer and suspected of de novo metastasis or recurrence were retrospectively identified from a prospective cohort enrolled for a postmarketing surveillance study of 18 F-FES at our institution. Per-patient diagnostic accuracy was assessed using pathology or 2 or more standard-of-care imaging procedures with a minimum of 6 months of follow-up as the reference standard. The per-region detection rate of 18 F-FES PET/CT was evaluated and compared with that of standard-of-care imaging.

Results: Of the 162 included patients, 104 and 58 were suspected to have recurrence or de novo metastasis, respectively. The overall sensitivity and specificity of 18 F-FES PET/CT were 95% (95% confidence interval [CI], 89%-98%) and 89% (95% CI, 76%-96%), respectively. When stratified according to clinical settings, the sensitivity and specificity were 95% (95% CI, 88%-99%) and 96% (95% CI, 78%-100%), respectively, for detecting recurrence, and 94% (95% CI, 81%-99%) and 82% (95% CI, 60%-95%) for detecting distant metastasis. In region-based analysis, the overall detection rate of 18 F-FES PET/CT was significantly higher than that of standard-of-care imaging (92% [95% CI, 89%-94%] vs 83% [95% CI, 79%-87%], P < 0.001).

Conclusions: 18 F-FES PET/CT showed excellent diagnostic performance in patients with ER-positive breast cancer suspected of de novo metastasis or recurrence.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RLU.0000000000005447DOI Listing

Publication Analysis

Top Keywords

f-fes pet/ct
24
breast cancer
12
metastasis recurrence
12
er-positive breast
12
novo metastasis
12
diagnostic accuracy
8
distant metastasis
8
patients er-positive
8
cancer suspected
8
suspected novo
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!