Rapid and quantitative CEST-MRI sequence using water presaturation.

Magn Reson Med

Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University, Beijing, China.

Published: February 2025

AI Article Synopsis

  • The study aims to improve CEST MRI, a method for metabolic imaging, by reducing long scan times and enhancing signal accuracy through a novel water-presaturation (WPS) technique.
  • The WPS CEST method helps erase residual signals from earlier scans, allowing faster recovery of the magnetization and enabling precise quantification with shorter repetition times (TR).
  • Results showed that WPS CEST provided consistent and accurate exchange rate measurements in simulations and human brain scans compared to conventional methods, thus promoting quicker and more reliable imaging.

Article Abstract

Purpose: Despite the significant potential for in vivo metabolic imaging in preclinical and clinical applications, CEST MRI suffers from long scan time and inaccurate quantification. This study aims to suppress the contaminations among signals under different frequencies, which could shorten the TR and thereby facilitate CEST imaging acceleration and quantification.

Methods: A novel sequence is proposed by applying a water-presaturation (WPS) module at the beginning of each TR. WPS CEST quickly knocks down the residual signal from previous TRs so that the magnetization of all TRs recovers from zero, which aligns well with the formula of quasi-steady-state theorem and enables accurate quantification within shorter TR. WPS CEST was assessed by simulations, creatine phantom, and healthy human brain scans at 3 T.

Results: In simulation and phantom experiment, WPS CEST allows accurate estimation of exchange rate (k) using omega plot and using shorter delay time (T) and saturation time (T) (e.g., 1 s/1 s) compared with the conventional CEST. Simulations further showed that WPS CEST could obtain consistent spin-lock relaxation (R) values over varied Ts and Ts. Six human scans indicated that R collected from conventional sequences showed significant differences between two groups with T and T of (1 s/1 s) and (2 s/2 s) (amide: 1.721 ± 0.051 s vs. 1.622 ± 0.050 s, p = 0.001; nuclear Overhauser enhancement: 1.792 ± 0.046 s vs. 1.687 ± 0.053 s, p = 0.004), whereas WPS CEST scans using these 2 T/T values obtained the same mean R (amide: 1.616 ± 0.053 s vs. 1.616 ± 0.048 s, p = 0.862; nuclear Overhauser enhancement: 1.688 ± 0.064 s vs. 1.684 ± 0.054 s, p = 0.544).

Conclusion: WPS CEST demonstrated accurate quantitation within shorter TR compared with conventional sequences, and thereby may allow rapid quantitative CEST scans in various situations.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.30309DOI Listing

Publication Analysis

Top Keywords

wps cest
24
cest
10
rapid quantitative
8
compared conventional
8
conventional sequences
8
nuclear overhauser
8
overhauser enhancement
8
cest scans
8
wps
7
quantitative cest-mri
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!