A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Collision cross sections of large positive fullerene molecular ions and their use as ion mobility calibrants in trapped ion mobility mass spectrometry. | LitMetric

Positive-ion laser desorption/ionization (LDI) of fullerenes contained in soot as produced by the Krätschmer-Huffman process delivers a wide range of fullerene molecular ions from C to above C. Here, the collision cross section (CCS) values of those fullerene molecular ions are determined using a trapped ion mobility-quadrupole-time-of-flight (TIMS-Q-TOF) instrument. While CCS values in the range from C to C are already known with high accuracy, those of ions from C onward had yet to be determined. The fullerene molecular ions covered in this work have CCS values from about 200 to 440 Å. The fullerene molecular ion series is evenly spaced at C differences in composition, and thus, small CCS differences of just 2.2-3.5 Å were determined across the entire range. Fullerene M ions may be employed as mobility calibrants, in particular, when very narrow 1/K ranges are being analyzed to achieve high TIMS resolving power. In addition, due to the simple elemental composition, M ions of fullerenes could also serve for mass calibration. This study describes the determination of CCS values of fullerene molecular ions from C to C and the application of ions from C to C to calibrate the ion mobility scale of a Bruker timsTOFflex instrument in any combination of LDI, matrix-assisted laser desorption/ionization (MALDI), and electrospray ionization (ESI) modes in the CCS range from about 200 to 420 Å. This use was exemplified along with ions from Agilent Tune Mix, leucine-enkephalin, angiotensin I, angiotensin II, and substance P.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11541393PMC
http://dx.doi.org/10.1007/s00216-024-05579-0DOI Listing

Publication Analysis

Top Keywords

fullerene molecular
24
molecular ions
20
ccs values
16
ion mobility
12
ions
10
collision cross
8
mobility calibrants
8
trapped ion
8
laser desorption/ionization
8
range fullerene
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!