Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Cholesterol is a fundamental lipid prevalent in eukaryotic cell membranes and circulating in the bloodstream bound to lipoproteins. It serves as a precursor to steroid hormones and is regarded as a biomarker for cardiovascular disease and other metabolic disorders. Numerous cholesterol detection methods predominantly rely on enzymes, which suffer from instability, leading to non-cost-effective biosensors with low sensitivity and poor reusability. Therefore, monitoring cholesterol levels with a feasible, rapid, and stable biosensor is critical for diagnosing and treating various disorders. This study aimed to develop a non-enzymatic cholesterol biosensor based on a selected cholesterol recognition peptide as the detection element. Screen-printed carbon electrodes (SPEs) modified with biocompatible poly-L-lactic acid (PLLA) porous nanomembranes (NMs) were utilized as support for the covalent immobilization of the peptide. Data obtained from electrochemical impedance spectroscopy (EIS) demonstrated the peptide's effective binding affinity towards cholesterol, paving the way for its implementation. The determination of cholesterol with the proposed biosensor exhibited a low limit of detection of 6.31 μM with linear responses ranging from 2-15 μM and 20-40 μM. These findings present an alternative method for cholesterol sensing by integrating novel peptides as biorecognition motifs with biocompatible polymeric materials, potentially useful as biocompatible and future point-of-care sensors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijbiomac.2024.136337 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!