Purpose: Percutaneous iliosacral (IS) screw fixation for pelvic ring injuries is a minimally invasive technique that reduces the amount of blood loss and shortens the procedure time. Moreover, two unilateral IS S1 screws exhibit superior stability to a single IS screw and are also safer for neurological injuries than an S2 screw. Therefore, this study aimed to evaluate fixation using percutaneous two unilateral IS S1 screws for pelvic ring injuries and its subsequent clinical outcomes.

Methods: We retrospectively reviewed 38 patients who underwent percutaneous two unilateral IS S1 screw fixation for pelvic ring injuries. The procedure time, blood loss, achievement of bone union, radiological outcomes (Matta and Tornetta grade), and postoperative complications were evaluated.

Results: The mean procedure time, hemoglobin loss, bone union rate, and time to union were 40.1 minutes (range, 18-102 minutes), 0.6 g/dL (range, 0.3-1.0 g/dL), 100%, and 153.2 days (range, 61-327 days), respectively. The Matta and Tornetta grades were excellent, good, and fair in 24 (63.1%), 11 (28.9%), and three patients (7.9%), respectively, and the postoperative complications were S1 screw loosening, widening of the symphysis pubis (2.3 and 2.5 mm), lumbosacral plexopathy, and S1 radiculopathy in one (2.6%), two (5.3%), one (2.6%), and one patient (2.6%), respectively. However, all neurological complications recovered spontaneously.

Conclusions: Percutaneous two unilateral IS S1 screw fixation was useful for treating pelvic ring injuries. In particular, it involved a short procedure time with little blood loss and also led to 100% bone union and good radiological outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11309362PMC
http://dx.doi.org/10.20408/jti.2021.0075DOI Listing

Publication Analysis

Top Keywords

pelvic ring
20
ring injuries
20
percutaneous unilateral
16
screw fixation
16
procedure time
16
fixation pelvic
12
blood loss
12
bone union
12
iliosacral screw
8
unilateral screws
8

Similar Publications

Background: Pelvic fractures often result in traumatic and intraoperative blood loss. Cell salvage (CS) is a tool where autologous blood lost during surgery is collected and recycled with anticoagulation, centrifugation to separate red blood cells, and washing to be reinfused back to the patient. The purpose of this study was to investigate our experience with CS in pelvic and acetabular surgery and its relationship to perioperative transfusion requirements.

View Article and Find Full Text PDF

Background And Purpose: A novel ring-gantry cone-beam computed tomography (CBCT) imaging system shows improved image quality compared to its conventional version, but its effect on autosegmentation is unknown. This study evaluates the impact of this high-performance CBCT on autosegmentation performance, inter-observer variability, contour correction times and delineation confidence, compared to the conventional CBCT.

Materials And Methods: Twenty prostate cancer patients were enrolled in this prospective clinical study.

View Article and Find Full Text PDF

Pelvic packing - status 2024.

Arch Orthop Trauma Surg

January 2025

Division of Orthopaedic Surgery, Oslo University Hospital, Oslo, Norway.

Patients with unstable hemodynamics and unstable pelvic ring injuries are still demanding patients regarding initial treatment and survival. Several concepts were reported during the last 30 years. Mechanical stabilization of the pelvis together with hemorrhage control offer the best treatment option in these patients.

View Article and Find Full Text PDF

Purpose: A prospective longitudinal cohort study was performed to gain insight into the course of recovery in terms of pain, opioid consumption, and mobility in patients with a lateral compression (LC) pelvic injury.

Methods: Adult patients with an LC injury, without any cognitive disorders or limited mobility and who could communicate in Dutch were asked to participate. Pain in terms of NRS (numeric rating scale, range 0-10), opioid use and mobility were recorded at eight time points: at hospital admission, and three days, one week, six weeks, three months, six months, one year and two years after the injury.

View Article and Find Full Text PDF

Iliosacral screw osteosynthesis - state of the art.

Arch Orthop Trauma Surg

January 2025

Department of Orthopedics and Traumatology, University Medical Center Mainz, Mainz, Germany.

Iliosacral screw osteosynthesis is a widely recognized technique for stabilizing unstable posterior pelvic ring injuries, offering notable advantages, including enhanced mechanical stability, minimal invasiveness, reduced blood loss, and lower infection rates. However, the procedure presents technical challenges due to the complex anatomy of the sacrum and the proximity of critical neurovascular structures. While conventional fluoroscopy remains the primary method for intraoperative guidance, precise preoperative planning using multiplanar reconstructions and three-dimensional volume rendering is crucial for ensuring accurate placement of iliosacral or transsacral screws.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!