The objective is to evaluate the parameters significantly related to calculating the power of the implanted lens and to determine the importance of different biometric, retina, and corneal aberrations variables. A retrospective cross-sectional observational study used a database of 422 patients who underwent cataract surgery at the Oftalvist Center in Almeria between January 2021 and December 2022. A random forest based on machine learning techniques was proposed to classify the importance of preoperative variables for calculating IOL power. Correlations were explored between implanted IOL power and the most important variables in random forests. The importance of each variable was analyzed using the random forest technique, which established a ranking of feature selections based on different criteria. A positive correlation was found with the random forest variables. Selection: axial length (AL), keratometry preoperative, anterior chamber depth (ACD), measured from corneal epithelium to lens, corneal diameter, lens constant, and astigmatism aberration. The variables coma aberration (p-value = 0,12) and macular thickness (p-value = 0,10) were almost slightly significant. In cataract surgery, the implanted IOL power is mainly correlated with axial length, anterior chamber depth, corneal diameter, lens constant, and preoperative keratometry. New variables such as astigmatism and anterior coma aberration and retina variables such as the preoperative central macular thickness could be included in the new generation of biometric formulas based on artificial intelligence techniques.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11461861 | PMC |
http://dx.doi.org/10.1038/s41598-024-74198-7 | DOI Listing |
BMC Ophthalmol
January 2025
Department of Ophthalmology, Eye & ENT Hospital, Fudan University, 83 Fenyang Road, Xuhui District, Shanghai, 200031, China.
Background: To investigate the impact of central corneal astigmatism on postoperative visual outcomes in patients with trifocal intraocular lens (IOL) implantation.
Methods: This retrospective study included 278 eyes of 278 patients who underwent uneventful cataract surgery with implantation of the trifocal IOL (AT LISA tri 839MP). Patients were divided into two groups according to the total corneal refractive power (TCRP) in 3 mm zone centered on the corneal apex: low astigmatism group, TCRP ≤ 0.
Klin Monbl Augenheilkd
January 2025
Department of Ophthalmology, Pallas Kliniken, Olten/Bern/Zürich/Dübendorf, Switzerland.
Background: Extended monovision is a novel mix-and-match approach that has been recently introduced. It involves implanting an aspherical monofocal intraocular lens (IOL) for distance vision in the dominant eye, and a bifocal extended depth-of-focus (EDOF) IOL in the nondominant eye. The target refraction for the nondominant eye is - 1.
View Article and Find Full Text PDFBackground: To determine whether accounting for posterior corneal surgically induced astigmatism (SIA) would improve toric intraocular lens power calculation prediction error.
Methods: A total of 189 eyes of 148 patients undergoing routine cataract surgery were included in the study. Standard and posterior keratometry were measured pre- and postoperatively.
PLoS One
January 2025
Department of Ophthalmology, Pennsylvania State University, Hershey, PA, United States of America.
Purpose: To investigate different measures for corneal astigmatism in the context of reconstructed corneal astigmatism (recCP) as required to correct the pseudophakic eye, and to derive prediction models to map measured corneal astigmatism to recCP.
Methods: Retrospective single centre study of 509 eyes of 509 cataract patients with monofocal (MX60P) IOL. Corneal power measured with the IOLMaster 700 keratometry (IOLMK), and Galilei G4 keratometry (GK), total corneal power (TCP2), and Alpin's integrated front (CorT) and total corneal power (CorTTP).
Diagnostics (Basel)
December 2024
Department of Ophthalmology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Republic of Korea.
Objectives: This study compared the visual outcomes and optical quality of two monofocal, aspheric intraocular lenses (IOLs; CT LUCIA 621P, Carl Zeiss Meditec; Eyhance ICB00, Johnson & Johnson Vision) by evaluating visual acuity, contrast sensitivity, and higher-order aberrations 1 month post-cataract surgery.
Methods: In this retrospective, comparative study, 120 eyes (72 patients) that underwent cataract surgery with either CT LUCIA 621P (Lucia group) or Eyhance ICB00 (Eyhance group) implantation (60 eyes/group) were retrospectively investigated. Visual acuity at various distances and defocus curves were measured 1 month postoperatively.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!