Development of a novel tool for high-precision focal irradiation using a clinical brachytherapy system.

Phys Med

Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea; Department of Radiation Oncology, Seoul National University College of Medicine, Seoul, Republic of Korea; Biomedical Research Institute, Seoul National University Hospital, Seoul, Republic of Korea. Electronic address:

Published: November 2024

AI Article Synopsis

  • The study focuses on the need for a targeted irradiation tool for small animals and compares its performance against a LINAC-based tool using a brachytherapy system.
  • A tungsten collimator was developed and tested for its dose delivery in mouse brains, utilizing measurements and simulations to ensure accuracy and effectiveness.
  • The results showed that the brachytherapy tool could precisely irradiate small areas of the mouse brain, confirming its potential use in detailed radiotherapy research for small animal studies.*

Article Abstract

Purpose: This study aims to emphasize the necessity of a focal irradiation tool for small animals and compare the beam characteristics of a tool developed using a brachytherapy system with a linear accelerator (LINAC)-based tool.

Methods: A 1-mm tungsten collimator was designed for a Ir-192 brachytherapy system. The percent depth dose (PDD) and horizontal profile of the collimator were measured and compared with a 4-mm commercial cone in the LINAC. Monte Carlo simulations validated all the measurements. Mouse brains were irradiated using a focal irradiation tool, and immunohistochemistry was performed on the brain samples to assess the dose accuracy.

Results: PDD showed that the maximum dose (d) for Ir-192 was at the surface in both measurements and simulations. At a depth of 1 mm, the collimator measured doses of 25.6 % and 21.0 %, respectively. At 6 MV in the LINAC, the d was observed at depths of 0.7 and 0.8 cm in measurements and simulations, respectively. The full width at half maximum (FWHM) at a depth of 1 mm was 1.0 and 1.1 mm for Ir-192 in the measurements and simulations, respectively. For small cone sizes at d, FWHM was 4.0 and 4.1 mm for the measurements and simulations, respectively. Immunohistochemistry results indicated that focal irradiation with Ir-192 affected small superficial brain areas while sparing the contralateral side and subventricular zone.

Conclusion: The focal irradiation tool accurately delivered doses to small regions and shallow depths in the mouse brain, making it valuable for precise radiotherapy during small animal experiments.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2024.104825DOI Listing

Publication Analysis

Top Keywords

focal irradiation
20
measurements simulations
16
brachytherapy system
12
irradiation tool
12
collimator measured
8
depth 1 mm
8
tool
5
focal
5
irradiation
5
small
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!