Download full-text PDF

Source
http://dx.doi.org/10.1080/00015385.2024.2410593DOI Listing

Publication Analysis

Top Keywords

pacing lead
4
lead entanglement
4
entanglement pulmonary
4
pulmonary artery
4
artery computed
4
computed tomography
4
tomography diagnosis
4
diagnosis management
4
pacing
1
entanglement
1

Similar Publications

Permanent Left Bundle Branch Area DF-4 Defibrillator Lead Implantation-Feasibility, Procedural Caveats, Safety, and Follow-Up.

J Cardiovasc Electrophysiol

January 2025

Department of Cardiac Electrophysiology and Pacing, Arrhythmia Heart Failure Academy, The Madras Medical Mission, Chennai, Tamil Nadu, India.

Introduction: Permanent implantation of a DF-4 implantable cardiac defibrillator (ICD) lead in the left bundle branch area (LBBA-ICD) is the next paradigm in amalgamating cardiac resynchronization therapy (CRT) and defibrillation. We systematically investigated feasibility/success rate, procedural caveats, and complications associated with a permanent DF-4 LBBA ICD implant and pertinent data at short-term follow-up.

Methods: We prospectively attempted implantation of 7 Fr Durata (Abbott, Chicago, IL, USA) single coil DF-4 ICD lead at the LBBA using a fixed-curve non-deflectable CPS locator delivery sheath.

View Article and Find Full Text PDF

Purpose: Pacemaker-related infections are serious complications of cardiac implantable electronic devices (CIEDs). This case report aims to describe the occurrence of pacemaker pocket infection and recurrent ventricular tachycardia (VT) in a Chinese amateur violinist with sick sinus syndrome (SSS), and to explore the possible connection between occupational habits and the infection, as well as VT.

Methods: A 76-year-old male violinist with a Biotronik Evia DR dual-chamber pacemaker presented with syncope and signs of a pacemaker pocket infection three years after implantation.

View Article and Find Full Text PDF

Unlabelled: Corrected transposition of the great arteries (c-TGA) is a congenital abnormality characterized by atrioventricular (AV) and ventriculoarterial discordance, associated with early and late-onset conduction disturbances. We report the case of a c-TGA patient affected by congenital complete AV block, with right ventricular lead malfunction with prolonged dwell time and two abandoned leads. He underwent leadless VDD pacemaker implantation at an unusual site (i.

View Article and Find Full Text PDF

More than 1 million permanent pacemakers are implanted worldwide each year, half of which are in patients with high-grade atrioventricular block. Pacemakers provide adequate frequency support in the initial stage, but traditional right ventricular (RV) pacing may lead to or aggravate left ventricular dysfunction and arrhythmia. Several potential risk factors for heart failure and arrhythmias after pacemaker surgery have been identified, but their occurrence remains difficult to predict clinically.