Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A new high-flow, compact aerosol concentrator, using rapid, turbulent mixing to grow aerosol particles into droplets for dry spot sample collection, has been designed and tested. The "TCAC (Turbulent-mixing, Condensation Aerosol Concentrator)" is composed of a saturator for generating hot vapor, a mixing section where the hot vapor mixes with the cold aerosol flow, a growth tube where condensational droplet growth primarily occurs, and a converging nozzle that focuses the droplets into a beam. The prototype concentrator utilizes an aerosol sample flow rate of 4 L min. The TCAC was optimized by varying the operating conditions, such as relative humidity of the aerosol flow, mixing flow ratio, vapor temperature, and impaction characteristics. The results showed that particles with a diameter ≥ 25 nm can be grown to a droplet diameter > 1400 nm with near 100% efficiency. Complete activation and growth were observed at relative humidity ≥ 25% of the aerosol sample flow. A consistent spot sample with a diameter of (the diameter of a circle containing 90% of the deposited particles) was obtained regardless of the aerosol particle diameter ( ). For fiber counting applications using phase contrast microscopy, the TCAC can reduce the sampling time, or counting uncertainty, by two to three orders of magnitude, compared to the 25-mm-filter collection. The study shows that the proposed mixing-flow scheme enables a compact spot sample collector suitable for handheld or portable applications, while still allowing for high flow rates.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11457491 | PMC |
http://dx.doi.org/10.1080/02786826.2024.2361050 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!