To comparing the accuracy of pedicle screw placement in posterior surgery for adult degenerative scoliosis (ADS) between robotic-assisted and traditional freehand techniques. This retrospective study included 92 patients with ADS who underwent posterior spinal surgery at the First Affiliated Hospital of Nanjing Medical University (Jiangsu Province Hospital) between March 2019 and December 2023. There were 19 males and 73 females with a mean age of (63.6±9.8) years. The patients were divided into two groups based on the technique used for pedicle screw placement: robot-assisted group (34 cases) and manual group (58 cases). Operative duration, intraoperative blood loss, facet joint violation, postoperative complications, magnitude of curve correction, visual analogue scale (VAS) and Oswestry Disability Index (ODI) scores preoperatively, 1 week postoperatively, and 1 month postoperatively were compared and analyzed between the two groups. The Gertzbein-Robbins classification criteria was used to assess the accuracy of screw placement. Differences in baseline data, operative duration, intraoperative blood loss, magnitude of curve correction, and VAS and ODI scores preoperatively, 1 week postoperatively, and 1 month postoperatively between the two groups exhibited no statistically significant differences (all >0.05). The accuracy of pedicle screw placement in the robot-assisted group was significantly higher than that in the manual group [90.9% (416/458) vs 80.1% (697/870), <0.001]. In terms of surgical segments, in T-T and L-S segments, the accuracy of pedicle screw placement in the robot group were both significantly higher than those in the control group [91.5% (130/142) vs 77.8% (186/239), =0.001; 90.3% (271/300) vs 80.8% (502/621), <0.001]. However, no significant differences was observed in the accuracy of S-alar-iliac (SAI) screw placement between the two groups [90.0%(9/10) vs 93.8%(15/16), =0.727]. Moreover, no significant differences was found in the deviation direction of the cortical screw penetration between both groups (=0.133). Significant differences were observed in the accuracy of screw placement between the Nash Moe 2 and 3 vertebral bodies in the robot group compared with those in the control group [88.9% (88/99) vs 71.0% (115/162), =0.001; 89.2% (83/93) vs 60.2% (68/113), <0.001]. Additionally, the incidence and grade of facet joint violation in the manual group were both significantly higher than those in the robot-assisted group (both <0.001). No statistically significant differences was identified in postoperative complications between the two groups (=0.841). It suggests that robot-assisted pedicle screw placement in posterior surgery for patients with ADS can significantly improve the accuracy of screw placement and reduce the incidence of facet joint violation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3760/cma.j.cn112137-20240130-00235 | DOI Listing |
The Latarjet procedure is a successful treatment for anterior shoulder instability with less than 5% having redislocations - revision surgery and prior surgery having been shown to be significant risk factors for recurrence. Approximately 90% of athletes return to play after Latarjet, comparable to arthroscopic Bankart repair. Patients may be physically unable to return to play, which may be due to persistent pain, apprehension, or weakness.
View Article and Find Full Text PDFJBJS Essent Surg Tech
January 2025
The Ohio State University College of Medicine, Columbus, Ohio.
Background: An all-inside endoscopic flexor hallucis longus (FHL) tendon transfer is indicated for the treatment of chronic, full-thickness Achilles tendon defects. The aim of this procedure is to restore function of the gastrocnemius-soleus complex while avoiding the wound complications associated with open procedures.
Description: This procedure can be performed through 2 endoscopic portals, a posteromedial portal (the working portal) and a posterolateral portal (the visualization portal).
JBJS Essent Surg Tech
January 2025
Department of Orthopaedic Surgery, Montefiore Medical Center, Bronx, New York.
Background: The pelvis is one of the most common areas for metastatic bone disease. We recently described the use of a minimally invasive percutaneous screw fixation of metastatic non-periacetabular pelvic lesions, with excellent results.
Description: The procedure can be completed in a standard operating theater without the need for special instruments.
Purpose: This retrospective study aimed to compare extended sinus lift and extramaxilla surgical protocols for restoring severely atrophic maxillae with zygomatic implants (ZIs) and evaluate their clinical effectiveness.
Materials And Methods: The study includes patients who were treated at a dental clinic in Italy from 2012 to 2022. These patients received fixed screw-retained complete dentures supported by either two or four zygomatic implants (ZIs).
Eur Spine J
January 2025
In Silico Biomechanics Laboratory, National Center for Spinal Disorders, Buda Health Center, Budapest, Hungary.
Purpose: The objective of this systematic review is to present a comprehensive summary of existing research on the use of 3D printing in spinal surgery.
Methods: The researchers conducted a thorough search of four digital databases (PubMed, Web of Science, Scopus, and Embase) to identify relevant studies published between January 1999 and December 2022. The review focused on various aspects, including the types of objects printed, clinical applications, clinical outcomes, time and cost considerations, 3D printing materials, location of 3D printing, and technologies utilized.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!