Inert gas washout methods have been shown to detect pathological changes in the small airways that occur in the early stages of obstructive lung diseases such as asthma and COPD. Numerical lung models support the analysis of characteristic washout curves, but are limited in their ability to simulate the complexity of lung anatomy over an appropriate time period. Therefore, the interpretation of patient-specific washout data remains a challenge. A new numerical lung model is presented in which electrical components describe the anatomical and physiological characteristics of the lung as well as gas-specific properties. To verify that the model is able to reproduce characteristic washout curves, the phase 3 slopes (S) of helium washouts are simulated using simple asymmetric lung anatomies consisting of two parallel connected lung units with volume ratios of , , and and a total volume flow of 250 ml/s which are evaluated for asymmetries in both the convection- and diffusion-dominated zone of the lung. The results show that the model is able to reproduce the S for helium and thus the processes underlying the washout methods, so that electrical components can be used to model these methods. This approach could form the basis of a hardware-based real-time simulator.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11517-024-03200-1DOI Listing

Publication Analysis

Top Keywords

washout methods
12
inert gas
8
gas washout
8
lung
8
numerical lung
8
characteristic washout
8
washout curves
8
lung model
8
electrical components
8
model reproduce
8

Similar Publications

A Double-Blind Randomized Crossover Trial Comparing the Esthetic Outcomes Of CAD-CAM Provisional Restorations Fabricated Using CBCT And IOS Acquisition Methods.

J Dent

December 2024

Professor and Clinic director, Clinic of General-, Special Care- and Geriatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich Switzerland. Electronic address:

Objectives: This double-blind randomised crossover trial aimed to compare the aesthetic outcomes of CAD-CAM manufactured provisional restorations created using cone beam computed tomography (CBCT) and intraoral scanners (IOS) acquisition methods.

Methods: Twelve participants (mean-age: 38 ± 5 years) requiring full mouth rehabilitation were included in this crossover trial. Two sets of identical CAD-CAM provisional restorations, differing only in the method of data acquisition (A: CBCT, B: IOS), were fabricated.

View Article and Find Full Text PDF

No FDA-approved medications for methamphetamine (MA) use disorder (MUD) are available. Suvorexant (SUVO), a dual orexin receptor antagonist that is FDA approved for insomnia treatment, reduces MA self-administration and MA-induced reinstatement responding in preclinical studies. SUVO may also reduce MA use by targeting substance use risk factors, including insomnia, stress, cue reactivity, and craving.

View Article and Find Full Text PDF

Background: Exercise-induced hypoalgesia (EIH) is characterized by a reduction in pain perception and sensitivity across both exercising and non-exercising body parts during and after a single bout of exercise. EIH is mediated through central and peripheral mechanisms; however, the specific effect of muscle contraction alone on EIH remains unclear. Moreover, previous studies on electrical muscle stimulation (EMS) have primarily focused on local analgesic effects, often relying on subjective pain reports.

View Article and Find Full Text PDF

Purpose: To evaluate the safety and efficacy of sublingual methazolamide in patients with open-angle glaucoma (OAG) and inform future trial design.

Methods: Fourteen participants (28 eyes) aged 50 to 90 years with bilateral OAG and intraocular pressure (IOP) between 18 and 35 mmHg after medication washout were included. Participants were randomized to receive either 25 mg or 50 mg of sublingual methazolamide once daily for one week, followed by twice-daily administration during the second week.

View Article and Find Full Text PDF

For two decades the ASCO CAP HER2 testing criteria have included 0 and 1+ scores, but this distinction was inconsequential. Now, based on the DESTINY Breast-04 Trial (DB-04) results, for patients with metastatic breast cancer it underpins eligibility for T-DXd treatment. Discerning 0 from 1+ IHC staining is challenging, as HER2 low is not a biologically distinct cancer subset, there are no reference standards or controls and second-tier tests do not apply.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!