Lipidomics is a well-established field, enabled by modern liquid chromatography mass spectrometry (LC-MS) technology, rapidly generating large amounts of data. Lipid extracts derived from biological samples are complex, and most spectral features in LC-MS lipidomics data sets remain unidentified. In-depth analyses of commercial triacylglycerol, diacylglycerol, and cholesterol ester standards revealed the expected ammoniated and sodiated ions as well as five additional unidentified higher mass peaks with relatively high intensities. The identities and origin of these unknown peaks were investigated by modifying the chromatographic mobile-phase components and LC-MS source parameters. Tandem MS (MS/MS) of each unknown adduct peak yielded no lipid structural information, producing only an intense ion of the adducted species. The unknown adducts were identified as low-mass contaminants originating from methanol and isopropanol in the mobile phase. Each contaminant was determined to be an alkylated amine species using their monoisotopic masses to calculate molecular formulas. Analysis of bovine liver extract identified 33 neutral lipids with an additional 73 alkyl amine adducts. Analysis of LC-MS-grade methanol and isopropanol from different vendors revealed substantial alkylated amine contamination in one out of three different brands that were tested. Substituting solvents for ones with lower levels of alkyl amine contamination increased lipid annotations by 36.5% or 27.4%, depending on the vendor, and resulted in >2.5-fold increases in peak area for neutral lipid species without affecting polar lipid analysis. These findings demonstrate the importance of solvent selection and disclosure for lipidomics protocols and highlight some of the major challenges when comparing data between experiments.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jasms.4c00320DOI Listing

Publication Analysis

Top Keywords

mobile phase
8
neutral lipid
8
lipid analysis
8
methanol isopropanol
8
alkylated amine
8
alkyl amine
8
amine contamination
8
lipid
6
phase contaminants
4
contaminants affect
4

Similar Publications

Background: The prevalence of hearing loss in infants in India varies between 4 and 5 per 1000. Objective-based otoacoustic emissions and auditory brainstem response have been used in high-income countries for establishing early hearing screening and intervention programs. Nevertheless, the use of objective screening tests in low- and middle-income countries (LMICs) such as India is not feasible.

View Article and Find Full Text PDF

The fluorescence detection of amino compounds and the evaluation of their content in environmental samples are vital, not only for assessing food quality but also for studying soil organic matter. Here, we present the synthesis and application of a novel fluorescent probe, 4-(9-acridone)benzylmethyl carbonochloride (APE-Cl), for detecting amino compounds via a chloroformate reaction with fluorescence detection. The complete derivatization reaction of APE-Cl with amino compounds can be accomplished in aqueous acetonitrile within 5 min at room temperature, using 0.

View Article and Find Full Text PDF

A Mobile App for Promoting Breastfeeding-Friendly Communities in Hong Kong: Design and Development Study.

JMIR Form Res

January 2025

School of Nursing, Li Ka Shing Faculty of Medicine, University of Hong Kong, 5/F, Academic Building, Pokfulam, Hong Kong, China (Hong Kong), 852 39176690.

Background: Breastfeeding is vital for the health and well-being of both mothers and infants, and it is crucial to create supportive environments that promote and maintain breastfeeding practices.

Objective: The objective of this paper was to describe the development of a breastfeeding-friendly app called "bfGPS" (HKU TALIC), which provides comprehensive territory-wide information on breastfeeding facilities in Hong Kong, with the goal of fostering a breastfeeding-friendly community.

Methods: The development of bfGPS can be categorized into three phases, which are (1) planning, prototype development, and preimplementation evaluation; (2) implementation and updates; and (3) usability evaluation.

View Article and Find Full Text PDF

Background And Aims: Physical activity is a key component of secondary stroke prevention. Mobile health (mHealth) interventions show promise for enhancing post-stroke physical activity, but most studies have combined mHealth with onsite services. This study evaluated the feasibility and acceptability of a fully digitalised mHealth intervention for physical activity among individuals post stroke or transient ischemic attack (TIA) in Sweden.

View Article and Find Full Text PDF

Background: Isotopologues resulting from the labelling of molecules with deuterium have attracted interest due to the isotope effect observed in chemistry and biosciences. Isotope effect may also play out in noncovalent interactions and mechanisms leading to intermolecular recognition. In chromatography, differences in retention time between isotopologues, as well as between isotopomers have been observed resulting in two different elution sequences (isotope effects): the normal isotope effect when heavier isotopologues retain longer than lighter analogues, and the inverse isotope effect featuring the opposite elution order.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?