A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Remote Orthotic Fabrication Method Using Small Three-Dimensional Printers and Computed Tomography Data: A Technical Report. | LitMetric

Introduction: Computer-aided design and manufacturing (CAD/CAM) methods have gained prominence in early orthotic provision. This study introduces an innovative approach using compact three-dimensional (3D) printers and computed tomography data to generate segmented body models for traditional Damen corset orthoses. The goals included evaluating the comfort and fit of orthoses and assessing the effectiveness of our approach for prosthetic companies with limited financial resources.

Materials And Methods: Lumbar and thoracolumbar orthoses were crafted via CAD/CAM. Four healthy patients wore the orthoses, with whom immediate and 1-week comfort and fit assessments were conducted. A prosthetist assessed fit, and the Japanese edition of OPUS-CSD, the Orthotics Prosthetics Users' Survey-Client Satisfaction with Device, was used for subjective assessment of comfort and fit.

Results: The fit evaluations were satisfactory for all patients with positive predefined criteria. Questionnaire responses confirmed high satisfaction and comfort, confirming a successful orthosis fit.

Conclusion: We established an orthotic fabrication method using CAD/CAM methods with 3D printers. Additionally, we confirmed the comfort and fit of the corsets so produced. The initial cost of 3D printers is lower than that of traditional carving machines, enabling even small-scale orthotic fabrication facilities to utilize CAD/CAM methods. Further research and refinements of this manufacturing approach are expected to expand its applicability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11625856PMC
http://dx.doi.org/10.5387/fms.23-00015DOI Listing

Publication Analysis

Top Keywords

orthotic fabrication
12
comfort fit
12
fabrication method
8
three-dimensional printers
8
printers computed
8
computed tomography
8
tomography data
8
cad/cam methods
8
comfort
5
fit
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!