A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effective doses of scout projections in maxillofacial cone beam computed tomography. | LitMetric

Objectives: To assess the effective and organ/tissue equivalent radiation doses of different scout projection protocols in four CBCT units.

Methods: Optically stimulated luminescence dosimeters (OSLD) were placed in reference anatomical locations in the head and neck segments of an anthropomorphic phantom representing an average adult male. Ten repeated exposures were obtained from each of the twelve scout projections studied, acquired from four maxillofacial cone beam computed tomography (CBCT) units (Midmark EIOS, 3D Accuitomo F170, Veraviewepocs 3D R100, and Veraview X800). The effective and organ/tissue equivalent doses were calculated for each protocol.

Results: Effective doses ranged from 0.7 µSv (Accuitomo F170 60 × 60 mm-anterior maxilla) to 6.9 µSv (Midmark 50 × 50 mm-anterior maxilla). The highest organ/tissue equivalent doses were recorded for the oral mucosa and salivary glands; however, the thyroid was the highest contributor to the effective dose, followed by the salivary glands.

Conclusions: Despite some variability among CBCT machines and protocols, the acquisition of scout projections is a low-dose procedure. The use of scout projections to ensure an adequate position of the region of interest within the field of view is highly desirable as they contribute minimally to overall CBCT patient dose.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00784-024-05971-1DOI Listing

Publication Analysis

Top Keywords

scout projections
16
organ/tissue equivalent
12
effective doses
8
doses scout
8
maxillofacial cone
8
cone beam
8
beam computed
8
computed tomography
8
effective organ/tissue
8
accuitomo f170
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!