A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Radiation dose to the eye of physicians during radio frequency catheter ablation: a small-scale study. | LitMetric

Background: Radio frequency catheter ablation (RFCA), a treatment for arrhythmia, requires a long fluoroscopy time that increases the radiation exposure dose to the physician, particularly to the lens of the eye. It is recommended that a lens-specific dosimeter such as DOSIRIS® is used to measure the dose to the lens.

Aims: In this study, we investigated whether conventional glass badges can be used as an alternative to lens dosimeters.

Methods: The doses to the lenses of two physicians (physician A, main operator; physician B, assistant; physician B was further away from the patient than physician A) were measured for 126 RFCA procedures performed over a 6-month period (fluoroscopy rate of 3.0 p/s with use of a ceiling-hanging shield).

Results: The cumulative value measured by a lens dosimeter attached to the inside of Pb glasses (0.07-mm dose equivalent) next to the left eye was 4.7 mSv for physician A, and 0.8 mSv for physician B. The reading on the glass badge worn on the left side of the neck was 4.7 mSv for physician A and 1.3 mSv for physician B. Lens dosimeter and glass badge values showed a good correlation for the left eye and left neck (r = 0.86, p < 0.01).

Conclusions: We show that glass badges may be a viable alternative to lens-equivalent dosimetry when using low-pulse fluoroscopy and a ceiling-hanging shield.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11845-024-03802-6DOI Listing
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11666769PMC

Publication Analysis

Top Keywords

physician
9
radio frequency
8
frequency catheter
8
catheter ablation
8
physician lens
8
lens dosimeter
8
left eye
8
47 msv physician
8
glass badge
8
radiation dose
4