Modified notching classification in inverted-bearing and conventional-bearing reverse total shoulder arthroplasty.

Arch Orthop Trauma Surg

Sporthopaedicum Straubing, Bahnhofplatz 27, 94315, Straubing, Germany.

Published: September 2024

Background: Scapular notching is a common complication of reverse total shoulder arthroplasty (RTSA). Although the notching rate has reduced significantly thanks to modifications to the surgical technique and humeral and glenoid components, uncontrollable polyethylene (PE)-induced osteolysis can still occur. In contrast to conventional-bearing (CB-RTSA), inverted-bearing RTSA (IB-RTSA) systems, with PE glenospheres and metal or ceramic humeral liners, avoid PE abrasion through scapulohumeral contact. If present, the resulting notch has a different size and configuration than with CB-RTSA. Thus, a modified notching classification seems reasonable. Even in CB-RTSA, the early stages of notching show a different configuration than implied by the established Nerot-Sirveaux classification; therefore, a modification of the classification system is recommended.

Methods: In a prospective multicentre study, 250 cases underwent IB-RTSA. Of these, 39 died, and 28 were lost to follow-up for other reasons, leaving 183 shoulders for the final follow-up examination at a mean of 120.7 months (range 84.1-172.4 months). In the CB-RTSA group, we retrospectively evaluated radiographs of 59 consecutive patients with a follow-up ranging from 2 to 7 years. We analysed the appearance, evolution over time, and location of bone loss on the scapular neck according to the modified Nerot-Sirveaux classification.

Results: In IB-RTSA, notching resulted in a new morphological configuration: In contrast to the Nerot-Sirveaux classification, notching began far from the baseplate as an impression or abrasion of the humeral component in the inferior scapular rim. Due to simultaneous mechanical ablation, the defect gradually enlarged, but usually did not contact the baseplate or extend beyond the inferior peg. No signs of PE-induced osteolysis were found. The notching rate reached 19% after 2 years and approached 36% after 10 years. Most shoulders had grade 0 notching (64%), followed by grade 1 (29%); extensive erosion (grade 4) was not observed. In the CB-RTSA group, a small bony impression or erosion without signs of PE-induced osteolysis was observed medial to the scapular neck, without contact with the metaglene in the early phase, which was similar to the impression of the humeral component in IB-RTSA. The notching rate was 86% for CB-RTSA.

Conclusions: A new classification was developed for IB-RTSA, which corresponds to the pathophysiological processes and is compatible with the existing Nerot-Sirveaux classification. Bone erosion in CB-RTSA is not adequately represented by the established classification in the early stages. For this reason, a supplement to the existing classification is presented.

Level Of Evidence: Level 4, Case Series, Treatment Study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11564281PMC
http://dx.doi.org/10.1007/s00402-024-05490-4DOI Listing

Publication Analysis

Top Keywords

notching rate
12
pe-induced osteolysis
12
nerot-sirveaux classification
12
classification
9
notching
9
modified notching
8
notching classification
8
reverse total
8
total shoulder
8
shoulder arthroplasty
8

Similar Publications

Genetic medicines, including CRISPR/Cas technologies, extend tremendous promise for addressing unmet medical need in inherited retinal disorders and other indications; however, there remain challenges for the development of therapeutics. Herein, we evaluate genome editing by engineered Cas9 ribonucleoproteins (eRNP) in vivo via subretinal administration using mouse and pig animal models. Subretinal administration of adenine base editor and double strand break-inducing Cas9 nuclease eRNPs mediate genome editing in both species.

View Article and Find Full Text PDF

NOTCH and IGF1 signaling systems are involved in the effects exerted by anthelminthic treatment of heifers on the bovine mammary gland.

Vet Parasitol

January 2025

Centro de Investigaciones Básicas y Aplicadas, Universidad Nacional del Noroeste de la Provincia de Buenos Aires, Junín, Buenos Aires 6000, Argentina; Centro de Investigaciones y Transferencia del Noroeste de la Provincia de Buenos Aires, CITNOBA, UNNOBA - UNSAdA - CONICET, Monteagudo 2772, Pergamino, Buenos Aires 2700, Argentina. Electronic address:

Dairy heifers with gastrointestinal nematodes have reduced growth rates, and delayed age at puberty and milk production onset related to late mammary gland development. IGF1 and Notch signaling systems are important in this process, and an altered profile of serum IGF1 has been associated with the detrimental effect of the nematodes on parenchymal development. In this context, we aimed to study the molecular mechanisms involved in bovine mammary gland development around pre and postpuberty, focusing on proliferative and angiogenic processes that involve the Notch and IGF1 pathways.

View Article and Find Full Text PDF

Acute Kidney Injury (AKI) is a significant medical condition characterized by the abrupt decline in kidney function.Low-intensity pulsed ultrasound (LIPUS), a non-invasive therapeutic technique employing low-intensity acoustic wave pulses, has shown promise in promoting tissue repair and regeneration. A novel LIPUS system was developed and evaluated in rat AKI models, focusing on its effects on glomerular filtration rate (GFR), blood urea nitrogen (BUN), serum creatinine (SCr), and the Notch1-Akt-eNOS signaling pathway.

View Article and Find Full Text PDF

Propagation of a Fatigue Crack Through a Hole.

Materials (Basel)

December 2024

University Coimbra, Centre for Mechanical Engineering, Materials and Processes (CEMMPRE), Department of Mechanical Engineering, 3030-788 Coimbra, Portugal.

The stop-hole technique is a well-known strategy to extend the fatigue life of cracked components. The ability to estimate fatigue life after the hole is important for safety reasons. The objective here is to develop strategies for the accurate prediction of initiation and propagation life ahead of the stop-hole.

View Article and Find Full Text PDF

Background Fracture of nickel-titanium (Ni-Ti) instruments in root canals is commonly associated with compromised outcomes in endodontic treatment. There is no single, universally accepted approach for managing this complication. The objective of this study is to evaluate the effectiveness of an Nd: YAP laser-assisted protocol in removing fractured Ni-Ti files in teeth with minimal root curvature (less than 15 degrees).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!