This paper presents the surface treatment results of titanium, veterinary bone wedges. The functional coating is composed of a porous oxide layer (formed by a plasma electrolytic oxidation process) and a polymer poly(sebacic anhydride) (PSBA) layer loaded with amoxicillin (formed by dip coatings). The coatings were porous and composed of Ca (4.16%-6.54%) and P (7.64%-9.89% determined by scanning electron microscopy with EDX) in the upper part of the implant. The titanium bone wedges were hydrophilic (54° water contact angle) and rough (surface area (Sa):1.16 μm) The surface tension determined using diiodomethane was 68.6 ± 2.0° for the anodized implant and was similar for hybrid coatings: 60.7 ± 2.2°. 12.87 ± 0.91 µg/mL of amoxicillin was released from the implants during the first 30 min after immersion in the phosphate-buffered saline (PBS) solution. This concentration was enough to inhibit the Staphylococcus aureus ATCC 25923, and Staphylococcus epidermidis ATCC12228 growth. The obtained inhibition zones were between 27.3 ± 2.1 mm-30.7 ± 0.6 mm when implant extract after 1 h or 4 h immersion in PBS was collected. Various implant biocompatibility analyses were performed under in vivo conditions, including pyrogen test (3 rabbits), intracutaneous reactivity (3 rabbits, 5 places by side), acute systemic toxicity (20 house mice), and local lymph node assay (LLNA) (20 house mice). The extracts from implants were collected in polar and non-polar solutions, and the tests were conducted according to ISO 10993 standards. The results from the in vivo tests showed, that the implant's extracts are not toxic (mass body change below 5%), not sensitizing (SI < 1.6), and do not show the pyrogen effect (changes in the temperature 0.15ºC). The biocompatibility tests were performed in a certificated laboratory with a good laboratory practice certificate after all the necessary permissions.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11452723 | PMC |
http://dx.doi.org/10.1038/s41598-024-72931-w | DOI Listing |
Arch Orthop Trauma Surg
January 2025
Department of Orthopaedic Surgery, Anam Hospital, Korea University College of Medicine, Seoul, South Korea.
Introduction: There is a lack of clinical evidence supporting the decision-making process between high tibial osteotomy (HTO) and unicomparmental knee arthroplasty (UKA) in gray zone indication, such as moderate medial osteoarthritis with moderate varus alignment. This study compared the outcomes between HTO and UKA in such cases and assessed the risk factor for not maintaining clinical improvements.
Materials And Methods: We retrospectively reviewed 65 opening-wedge HTOs and 55 UKAs with moderate medial osteoarthritis (Kellgren-Lawrence grade ≥ 3 and Ahlback grade < 3) and moderate varus alignment (5°< Hip-Knee-Ankle angle < 10°) over 3 years follow-up.
J Clin Med
December 2024
Bielefeld University, Medical School and University Medical Center OWL, Protestant Hospital of the Bethel Foundation, Department of Trauma Surgery and Orthopedics, 33617 Bielefeld, Germany.
Medial opening wedge high tibial osteotomy (HTO) treats medial knee osteoarthritis by realigning the knee joint, though it still carries quite a high risk of complications. A new Variable Fixation Locking Screw technology, designed to gradually reduce construct stiffness and promote bone healing, aims to address these issues. This observational study evaluates the safety and effectiveness of this innovative approach in improving clinical outcomes.
View Article and Find Full Text PDFBMC Musculoskelet Disord
January 2025
Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Hebei, Shijiazhuang, 050051, P.R. China.
Background: It is known that open wedge high tibial osteotomy (OWHTO) may lead to progression of patellofemoral degeneration due to descent of the patellar height. However, the difference in patellofemoral joint (PFJ) loads with normal daily activity between uniplane and biplane osteotomies is unclear. The purpose of this study was to reveal the differences in PFJ biomechanics between uniplane and biplane OWHTO using finite element analysis (FEA).
View Article and Find Full Text PDFProc Natl Acad Sci U S A
January 2025
National Key Laboratory of Space Medicine, China Astronaut Research and Training Center, Beijing 100094, China.
TMEM16A, a key calcium-activated chloride channel, is crucial for many physiological and pathological processes such as cancer, hypertension, and osteoporosis, etc. However, the regulatory mechanism of TMEM16A is poorly understood, limiting the discovery of effective modulators. Here, we unveil an allosteric gating mechanism by presenting a high-resolution cryo-EM structure of TMEM16A in complex with a channel inhibitor that we identified, Tamsulosin, which is resolved at 2.
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2024
Department of Orthopaedic Surgery, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing, People's Republic of China.
Background: Gorham-Stout disease (GSD) is a rare disease characterized by osteolysis and lymphatic malformations. GSD involving the spine is exceptionally rare and lacks a standard cure. The aim of this article was to report a case of GSD with scoliosis treated via corrective surgery and medication.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!