Fecal contamination of surface water compromises the usability of surface water for drinking water production due to an increase in human health risks. In this study, we collected surface water samples for two years from the Kokemäki River (Finland). The downstream river stretch is used for feeding production of artificial ground water for a major drinking water treatment plant. The prevalence of Campylobacter species and Salmonella serotypes together with fecal source identifiers targeting general, human, gull, swine, and ruminant were evaluated at 16 sampling sites throughout the studied watershed. We detected Campylobacter spp. from all 16 sampling sites with Campylobacter jejuni and Campylobacter lari as the most detected species. Salmonella spp. was detected in 10 out of 16 sampling sites, with Salmonella Typhimurium being the most common serovar. Regarding spatial variation in the hygienic quality of surface water, the upstream area (urban proximity) and downstream area (agricultural proximity) had higher microbial loads than the middle section of the study area. Samples taken in fall and spring had higher microbial loads than summer and winter samples. The lower ratio of rRNA to rRNA-gene (rDNA) of studied microbes in the winter than in other seasons may indicate low metabolic activity of bacterial targets during winter. The number of gulls, swine, and cattle in the catchment area concorded with the number of fecal source identifiers in the surface water. Further, the prevalence of gull-specific source identifier agreed with the detection of C. coli, C. lari, and S. Typhimurim, whereas the prevalence of swine- and ruminant-specific source identifiers agreed with the detection of C. jejuni and C. coli. Thus, fecal source identifiers are shown to be important tools for monitoring zoonotic pathogens affecting microbial quality of surface water. Further, variation in fecal loads indicates such variation in health risks related to surface water use.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.scitotenv.2024.176559 | DOI Listing |
ACS Appl Mater Interfaces
January 2025
Center of Nanomaterials for Renewable Energy, State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi'an Jiaotong University, Xìan, Shaanxi 710049, China.
Prussian blue analogues (PBAs) show great promise as cathode candidates for aqueous zinc-ion batteries thanks to their high operating voltage, open-framework structure, and low cost. However, suffering from numerous vacancies and crystal water, the electrochemical performance of PBAs remains unsatisfactory, with limited capacity and poor cycle life. Here, a simple coprecipitation method is shown to synthesize well-crystallized cobalt hexacyanoferrate (CoHCF) with a small amount of water and high specific surface area.
View Article and Find Full Text PDFJ Bone Joint Surg Am
January 2025
Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY.
Background: Antiseptic solutions are commonly utilized during total joint arthroplasty (TJA) to prevent and treat periprosthetic joint infection (PJI). The purpose of this study was to investigate which antiseptic solution is most effective against methicillin-sensitive Staphylococcus aureus (MSSA) and Escherichia coli biofilms established in vitro on orthopaedic surfaces commonly utilized in total knee arthroplasty: cobalt-chromium (CC), oxidized zirconium (OxZr), and polymethylmethacrylate (PMMA).
Methods: MSSA and E.
Int Endod J
January 2025
School of Medicine and Dentistry, Griffith University, Gold Coast, Australia.
Introduction: Biofilms may show varying adherence strengths to dentine. This study quantified the shear force required for the detachment of multispecies biofilm from the dentine using fluid dynamic gauging (FDG) and computation fluid dynamics (CFD). To date this force has not been quantified.
View Article and Find Full Text PDFChempluschem
January 2025
Kaiserslautern University of Technology: Rheinland-Pfalzische Technische Universitat Kaiserslautern-Landau, Chemistry, 67663, Kaiserslautern, GERMANY.
We report the synthesis of a series of detergents with a lactobionamide polar head group and a tail containing four to seven perfluorinated carbon atoms. Critical micellar concentrations (CMCs) were determined using isothermal titration calorimetry (ITC) and surface tension (SFT) measurements, showing a progressive decrease from 27 mM to about 0.2 mM across the series.
View Article and Find Full Text PDFEnviron Health Perspect
January 2025
Silent Spring Institute, Newton, Massachusetts, USA.
Background: Unregulated contaminants in drinking water, such as per- and polyfluoroalkyl substances (PFAS), can contribute to cumulative health risks, particularly in overburdened and less-advantaged communities. To our knowledge, there has been no nationwide assessment of socioeconomic disparities in exposures to unregulated contaminants in drinking water.
Objective: The goals of this study were to identify determinants of unregulated contaminant detection among US public water systems (PWSs) and evaluate disparities related to race, ethnicity, and socioeconomic status.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!