Inverse dynamic analysis is a technique used during gait analysis to estimate intersegmental forces and net joint moments. Inverse dynamic calculations are susceptible to various forms of error. One such error is force plate drift, often produced by humidity condensing within the input connectors and electronics, causing an undesired change in output over time. This can be particularly concerning for movement laboratories where inverse dynamics are considered in clinical decision-making processes. Manufacturers will provide tolerance levels for drift. However, levels of acceptable drift are rarely considered from a clinical perspective. Therefore, this study aims to establish clinically acceptable limits of force plate drift error, induced by applying systematic errors to force plate channels, on predicted lower limb joint moments during gait. Gait data of 10 children with typical development were analysed and induced errors of 0.5 N, 1 N, 1.5 N, 3 N, 6 N and 12 N were incrementally applied to the horizontal and vertical force channels. Data were recalculated for each increment and mean profiles compared to an error free mean (±1SD) band. Error was deemed clinically significant when moments fell outside the mean (±1SD) band. Induced error at 6 N and above was sufficient to cause a clinically significant change. Sagittal and coronal plane moments at the hip were most affected, followed by the knee and then the ankle. While manufacturer guidelines for acceptable drift are usually well below 6 N, care is needed when using force plates over several minutes or more as drift may eventually exceed clinically acceptable limits.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiomech.2024.112351 | DOI Listing |
Sci Rep
December 2024
Neuromuscular Research Lab, Interdisciplinary Centre for the study of Human Performance (CIPER), Faculty of Human Kinetics, University of Lisbon, 1499-002, Oeiras, Portugal.
Changes in postural control associated with clinical practice or specific conditions such as the presence of neck pain remain unexplored in dental students. Therefore, this study aimed to explore the time-course changes in postural control complexity among dental students enrolled in clinical practice, comparing those with and without neck pain. We used an online Nordic Musculoskeletal Questionnaire for group allocation and center of pressure (CoP) oscillations with a tri-axial Bertec force plate.
View Article and Find Full Text PDFClin Biomech (Bristol)
December 2024
Masuhara Clinic, 3-4-2, Tenmabashi, Kita-ku, Osaka 530-0042, Japan.
Background: Few studies have assessed vertical ground reaction force, contact time, contact area, and center of pressure during gait in the early phase post-total hip arthroplasty. This study aimed to investigate whether these parameters are more pronounced in participants post-total hip arthroplasty compared to healthy controls.
Methods: We included 22 female participants who underwent total hip arthroplasty (age, 68.
Sports (Basel)
December 2024
Research Center for Sport and Health Sciences, University of Iceland, 102 Reykjavik, Iceland.
Given the increasing use of innovative force plate systems in applied sports settings and the impact that anterior cruciate ligament (ACL) injuries have on team success, the purpose of the present study was to compare the lower-body neuromuscular performance characteristics of athletes who underwent ACL reconstruction (ACLR) and their non-injured counterparts (i.e., healthy controls).
View Article and Find Full Text PDFSports (Basel)
November 2024
Sport, Performance, and Nutrition Research Group, School of Allied Health, Human Services and Sport, La Trobe University, Melbourne, VIC 3086, Australia.
Ground reaction forces (GRFs) are known to be high during front foot contact of fast bowling deliveries in cricket. There is a lack of published data on the GRFs during follow through foot contacts. The aim of this study was to quantify and compare peak GRFs and impulse of the delivery stride and the follow through of fast bowling deliveries.
View Article and Find Full Text PDFJ Funct Morphol Kinesiol
December 2024
Escuela de Ciencias de la Actividad Física, El Deporte y la Salud, Facultad de Ciencias Médicas, Universidad de Santiago de Chile, Santiago 8370003, Chile.
Assessing the reliability of measurement instruments and equipment is essential to ensure the accurate tracking of athletes over extended periods, minimizing the measurement errors caused by chance or other factors. However, a less common but equally important analysis is the verification of inter-measurement agreement, which complements the reliability results. To evaluate the intra- and inter-test reliability of an isometric hip adduction strength and asymmetries test in professional soccer players.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!