Pupillary responses serve as sensitive indicators of cognitive processes, attentional shifts and decision-making dynamics. Our study investigates how directional uncertainty and target speed ( ) influence pupillary responses in a foveal tracking task involving the interception of a moving dot. Directional uncertainty, reflecting the unpredictability of the target's direction changes, was manipulated by altering the angular range (AR) from which random directions for the moving dot were extracted. Higher AR values were associated with reduced pupillary diameters, indicating that heightened uncertainty led to smaller pupil sizes. Additionally, an inverse U-shaped relationship between and pupillary responses suggested maximal diameters at intermediate speeds. Analysis of saccade-triggered responses showed a negative correlation between pupil diameter and directional uncertainty. Dynamic linear modelling revealed the influence of past successful collisions and other behavioural parameters on pupillary responses, emphasizing the intricate interaction between task variables and cognitive processing. Our results highlight the dynamic interplay between the directional uncertainty of a single moving target, and pupillary responses, with implications for understanding attentional mechanisms, decision-making processes and potential applications in emerging technologies.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11444787 | PMC |
http://dx.doi.org/10.1098/rsos.240606 | DOI Listing |
J Oral Facial Pain Headache
December 2024
Neuroscience of Emotion Cognition and Nociception Group (NeuroCEN Group), Faculty of Odontology, Complutense University of Madrid, 28040 Madrid, Spain.
The aims of the study are to analyze the influence of pain and no pain expectations on the physiological (electromyography (EMG) and pupillometry) and cognitive (Numerical Rating Scale (NRS)) response to pain. Pain expectation and no pain expectation situations were induced by employing instructional videos. The induction of pain was performed by palpating the masseter with an algometer in a sample of 2 groups: 30 healthy participants (control group) and 30 patients (Temporomandibular disorders (TMD) group) with chronic myofascial pain with referral in the masseter muscle (Diagnostic Criteria for Temporomandibular Dissorders (DC/TMD)).
View Article and Find Full Text PDFTrends Hear
January 2025
Faculty of Medicine and University Hospital Cologne, Department of Otorhinolaryngology, Head and Neck Surgery, University of Cologne, Cologne, Germany.
Speech-on-speech masking is a common and challenging situation in everyday verbal communication. The ability to segregate competing auditory streams is a necessary requirement for focusing attention on the target speech. The Visual World Paradigm (VWP) provides insight into speech processing by capturing gaze fixations on visually presented icons that reflect the speech signal.
View Article and Find Full Text PDFActa Psychol (Amst)
January 2025
Department of Neuroscience, Psychology, Pharmacology and Child Health (NEUROFARBA), University of Florence, Florence, Italy.
The objective assessment of cognitive processes is of critical importance to understanding the mechanisms underlying various mental functions and dysfunctions. In recent years, the technological innovations related to the eye-tracking industry made the time right to organically integrate pupillometry in the assessment of cognitive profiles. Here, we review evidence showing that pupillometry offers a uniquely sensitive biomarker of the functioning of several distinct networks, cognitive functions, emotional states, and individual differences in their instantiation.
View Article and Find Full Text PDFJ Clin Med
December 2024
The David J Apple Center for Vision Research, Department of Ophthalmology, Heidelberg University Eye Clinic, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.
This laboratory study aims to assess the effects of misaligning different trifocal intraocular lenses (IOLs) under varying spectral and corneal spherical aberration (SA) conditions. With an IOL metrology device under monochromatic and polychromatic conditions, the following models were studied: AT ELANA 841P, AT LISA Tri 839MP, FineVision HP POD F, Acrysof IQ PanOptix, and Tecnis Synergy ZFR00V. The SA was simulated using an aberration-free and average-SA cornea.
View Article and Find Full Text PDFJ Exp Child Psychol
January 2025
Department of Psychology, Ludwig Maximilians Universität München, 80802 Munich, Germany; Department of Psychology, Universität Wien, 1010 Wien, Austria.
We investigated the relationships among the moral self-concept, arousal reactions to third-party moral situations, and moral judgment in 5- to 7-year-old children (N = 59). Children's moral self-concept was assessed using a puppet task. In addition, children were shown audiovisual scenes depicting prosocial, antisocial, and neutral interactions between children.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!