A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Right ventriculography to guide left bundle branch pacing in pacing-induced cardiomyopathy: a novel case report. | LitMetric

Background: There is emerging evidence for the potential utility of left bundle branch area pacing (LBBAP), as an alternative to conventional cardiac resynchronization therapy (CRT). The utility of right ventriculography by way of power injector to facilitate lead placement has not yet been reported in the literature.

Case Summary: A 79-year-old female, with a background of poorly rate-controlled atrial fibrillation, presented with worsening dyspnoea. She had recently undergone single-chamber pacemaker insertion prior to an atrioventricular nodal (AVN) ablation, owing to failure in achieving successful CRT coronary sinus lead placement. She had clinical evidence of volume overload, and her electrocardiogram demonstrated right ventricular pacing. Echocardiography demonstrated left ventricular (LV) impairment, with an ejection fraction (EF) of 35%, and severe functional mitral regurgitation (MR). Her diagnosis was overall consistent with pacing-induced cardiomyopathy (PIC). In this patient, the use of right ventriculography, using power-injector-delivered contrast, successfully facilitated placement of an LBBAP lead, with confirmation of good threshold and sensing parameters. Following an upgrade to conduction system pacing, the patient recovered well. On recent follow-up, repeat echocardiography (24 months post initial presentation) demonstrated improved LV function (EF 45% from 35%) and only mild-to-moderate MR.

Discussion: In conclusion, we demonstrate the utility of right ventriculography to facilitate placement of an LBBAP lead, successfully treating a patient who developed PIC from chronic right ventricular pacing following AVN ablation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11443961PMC
http://dx.doi.org/10.1093/ehjcr/ytae494DOI Listing

Publication Analysis

Top Keywords

left bundle
8
bundle branch
8
pacing-induced cardiomyopathy
8
utility ventriculography
8
lead placement
8
avn ablation
8
ventricular pacing
8
placement lbbap
8
lbbap lead
8
pacing
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!