Comparison of three approaches for treating the bony access window in lateral sinus floor elevation: a retrospective analysis.

Sci Rep

Department of Periodontology, Periodontal-Implant Clinical Research Institute, Kyung Hee University College of Dentistry, Kyung Hee University Medical Center, 23 Kyungheedae-ro, Dongdaemun-gu, Seoul, 02447, Korea.

Published: October 2024

The aim of this study was to retrospectively determine the effects of applying different treatment methods to the bony access window on the healing outcomes in lateral sinus floor elevation (SFE). Lateral SFE with implant placement was performed in 131 sinuses of 105 patients. The following three treatment methods were applied to the bony access window: application of a collagen barrier (group CB), repositioning the bone fragment (group RW) and untreated (group UT). Radiographic healing in the window area, augmented bone height changes and marginal bone level changes were examined. Mixed logistic and mixed linear models were analyzed. Over 4.3 ± 1.4 years of follow-up, the implant survival rate was 100% in groups CB and UT, and 96.9% in group RW. The treatment applied to the window did not significantly influence the radiographic healing in the window area, augmented bone height changes or marginal bone level changes (p > 0.05). The healed window areas had generally flat morphologies and were fully corticalized. The mean changes in the augmented bone were less than 1.5 mm in all groups. Marginal bone level changes were minimal. In conclusion, Healing outcomes were not different among three different methods to treat the bony access window in lateral SFE.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11446933PMC
http://dx.doi.org/10.1038/s41598-024-74076-2DOI Listing

Publication Analysis

Top Keywords

bony access
16
access window
16
augmented bone
12
marginal bone
12
bone level
12
level changes
12
window
8
window lateral
8
lateral sinus
8
sinus floor
8

Similar Publications

Healing by secondary intention over NeoDura applicated on a craniectomy defect: a case report and literature review.

J Med Case Rep

December 2024

UZ Leuven, Plastic, Reconstructive and Aesthetic Surgery, Herestraat 49, 3000, Louvain, Belgium.

Background: NeoDura (Medprin Biotech Gmbh) is an absorbable dural repair patch consisting of degradable poly-L-lactic acid and porcine gelatin that provides a hermetic closure of the dura mater (Medprin Biotech. Neodura. Dural Repair Patch [Brochure].

View Article and Find Full Text PDF

In percutaneous pelvic trauma surgery, accurate placement of Kirschner wires (K-wires) is crucial to ensure effective fracture fixation and avoid complications due to breaching the cortical bone along an unsuitable trajectory. Surgical navigation via mixed reality (MR) can help achieve precise wire placement in a low-profile form factor. Current approaches in this domain are as yet unsuitable for real-world deployment because they fall short of guaranteeing accurate visual feedback due to uncontrolled bending of the wire.

View Article and Find Full Text PDF

Objective: Post-traumatic tibial bone defects represent a significant challenge to orthopedic surgeons. Various reconstructive methods are available based on associated local soft tissue injury and defect size. Free vascularized fibular graft represents a major successful technique; combined with a rigid Ilizarov external fixator, it allows safe, immediate postoperative weight bearing.

View Article and Find Full Text PDF

Bony Stroke on Rheumatoid Arthritis: A Rare Entity or a Missed Diagnosis?

Cureus

November 2024

Neuroradiology Department, Unidade Local de Saúde de São João, Porto, PRT.

Bone or cartilage anomalies affecting the arteries supplying the brain can be a structural cause of ischemic stroke. Due to their rarity, there is currently no standardized approach for evaluating and treating these so-called bony strokes. We present a case of a 79-year-old woman with a history of cranial settling due to rheumatoid arthritis (RA) and moderate disability, who presented with insidious dizziness and gait disturbances over three weeks.

View Article and Find Full Text PDF

Based on the available literature, duplicated internal auditory canals (DIACs) represent an exceedingly rare temporal bone anomaly that can result in sensorineural hearing loss (SNHL) in the pediatric population. Often associated with a hypoplastic or aplastic cochlear nerve, DIAC poses limitations on treatment options, such as cochlear implants, for affected patients. Accurate diagnosis and optimal management necessitate a thorough assessment of inner ear structures and potential neural abnormalities with high-resolution computed tomography and magnetic resonance imaging of the temporal bones.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?