A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Retrospective analysis of treatment-positioning accuracy and dose error in boron neutron capture therapy using a sitting-position treatment system for head and neck cancer. | LitMetric

The neutron beam in boron neutron capture therapy (BNCT) exhibits poor directionality and significantly decreasing neutron flux with increasing distance. Therefore, the treatment site must be close to the irradiation aperture. Some patients with head and neck cancer may benefit from a sitting-position setup. The study aim was to evaluate the treatment-positioning accuracy and dose error in sitting patients receiving BNCT. Thirty-two patients with head and neck cancer who underwent sitting-position BNCT at Southern Tohoku BNCT Research Center were included in the study. Horizontal (ΔX) and vertical (ΔY) errors were defined as the displacement between the treatment planning system (TPS) digital reconstructed radiograph and the pre-treatment X-ray image. Using in-house software, image matching was performed. The beam-axial directional (ΔZ) error was compared with the parameters entered into the TPS and the actual pre-treatment measured values. The translational-position error was reflected in the TPS's patient coordinate system with respect to the reference plan. Re-dose calculations were performed to evaluate the effect of positional error on tumor and normal-tissue doses. The [ΔX, ΔY, ΔZ] mean ± 1SD were - 0.40 ± 2.0, 0.30 ± 2.3, and - 1.4 ± 1.5 mm, respectively. The D and D tumor-dose errors were 1.22 % ± 1.44 % and 0.99 % ± 1.63 %, respectively. The D pharyngeal and oral mucosal-dose errors were 0.98 % ± 1.91 % and 1.21 % ± 1.78 %, respectively. The tumor- and normal-tissue dose errors were typically < 5 %. High-precision treatment was feasible in sitting-positioned BNCT.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejmp.2024.104818DOI Listing

Publication Analysis

Top Keywords

head neck
12
neck cancer
12
treatment-positioning accuracy
8
accuracy dose
8
dose error
8
boron neutron
8
neutron capture
8
capture therapy
8
patients head
8
error
5