Since desorption electrospray ionization mass spectrometry (DESI-MS) was first presented in 2004, the fundamental design of the sprayer has undergone relatively minor modifications. This changed in 2022 when Takats and co-workers implemented the desorption electro-flow focusing (DEFFI) sprayer design by modifying the sprayer from a commercial DESI system, leading to significantly improved spatial resolution and robustness compared with the traditional DESI-MSI sprayer design. Here, we present the design of a new DEFFI sprayer that can be built from standard fittings and connectors in combination with an aluminum spray head that can be machined in most mechanic workshops. The new design represents a cost-efficient approach to improved DESI-MSI on mass spectrometers from all vendors, including high-resolution instruments such as Orbitraps and FT-ICR. The new DEFFI sprayer is demonstrated on a QExactive Orbitrap mass spectrometer, resulting in a massively improved ion yield compared with the classic DESI sprayer. The improved ion yield enables DESI-MSI at ion injection times down to 5 ms, allowing for DESI-MSI at a potentially very high speed. More importantly, the DEFFI sprayer delivers a more robust and focused spray, which is easier to use and requires less optimization. It provides high spatial resolution with limited effort compared with previous modifications of the traditional DESI design. Imaging of rat testis was performed at pixel sizes down to 12 μm, suggesting a spatial resolution of approximately 30 μm, which may have potential for further improvement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/jasms.4c00341 | DOI Listing |
Sci Data
January 2025
Department of Earth and Environmental Engineering, Columbia University, New York, USA.
The Gravity Recovery and Climate Experiment (GRACE) and its follow-on (GRACE-FO) missions have provided estimates of Terrestrial Water Storage Anomalies (TWSA) since 2002, enabling the monitoring of global hydrological changes. However, temporal gaps within these datasets and the lack of TWSA observations prior to 2002 limit our understanding of long-term freshwater variability. In this study, we develop GRAiCE, a set of four global monthly TWSA reconstructions from 1984 to 2021 at 0.
View Article and Find Full Text PDFSci Rep
January 2025
Mallinckrodt Institute of Radiology, Washington University School of Medicine, 4515 McKinley Ave., St. Louis, MO, 63110, USA.
Functional magnetic resonance imaging (fMRI) has dramatically advanced non-invasive human brain mapping and decoding. Functional near-infrared spectroscopy (fNIRS) and high-density diffuse optical tomography (HD-DOT) non-invasively measure blood oxygen fluctuations related to brain activity, like fMRI, at the brain surface, using more-lightweight equipment that circumvents ergonomic and logistical limitations of fMRI. HD-DOT grids have smaller inter-optode spacing (~ 13 mm) than sparse fNIRS (~ 30 mm) and therefore provide higher image quality, with spatial resolution ~ 1/2 that of fMRI, when using the several source-detector distances (13-40 mm) afforded by the HD-DOT grid.
View Article and Find Full Text PDFMagn Reson Imaging
January 2025
Department of Medical Imaging, Pingyin people's Hospital, Jinan 250400, China.
Magnetic Resonance Imaging is a cornerstone of medical diagnostics, providing high-quality soft tissue contrast through non-invasive methods. However, MRI technology faces critical limitations in imaging speed and resolution. Prolonged scan times not only increase patient discomfort but also contribute to motion artifacts, further compromising image quality.
View Article and Find Full Text PDFUltramicroscopy
January 2025
Mechanical Engineering, University of Michigan, USA.
The objective of this work was to explore the capabilities of a field emission gun scanning electron microscope (FEG-SEM) equipped with a transmission scanning electron detector (TSEM) and energy dispersive spectroscopy (EDS) to identify nanoscale chemical heterogeneities in a gas atomization reaction synthesis (GARS) steel sample. The results of this analysis were compared to the same study conducted with scanning transmission electron microscopy (STEM) with EDS mapping. TSEM-EDS was performed using the standard spectral analysis approach, i.
View Article and Find Full Text PDFSci Total Environ
January 2025
Universidad de Santiago de Chile, Santiago, Chile.
Assessing future snow cover changes is challenging because the high spatial resolution required is typically unavailable from climate models. This study, therefore, proposes an alternative approach to estimating snow changes by developing a super-spatial-resolution downscaling model of snow depth (SD) for Japan using a convolutional neural network (CNN)-based method, and by downscaling an ensemble of models from the Coupled Model Intercomparison Project Phase 6 (CMIP6) dataset. After assessing the coherence of the observed reference SD dataset with independent observations, we leveraged it to train the CNN downscaling model; following its evaluation, we applied the trained model to CMIP6 climate simulations.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!