Accuracy of implant abutment level digital impressions using stereophotogrammetry in edentulous jaws: an in vitro pilot study.

BMC Oral Health

Shanghai Engineering Research Center of Tooth Restoration and Regeneration & Tongji Research Institute of Stomatology & Department of Implantology, Stomatological Hospital, Dental School, Tongji University, Shanghai, China.

Published: October 2024

Background: In edentulous jaws, factors such as the number of implants, cross-arch distribution, and the angle among implants may affect the accuracy of the implant impression. This study explored factors influencing the accuracy of implant abutment-level digital impressions using stereophotogrammetry in edentulous jaws.

Methods: Two standard all-on-4 and all-on-6 models of edentulous jaws were constructed in vitro. In the stereophotogrammetry group (PG), the implant digital impression was made using stereophotogrammetry and saved as an STL file. In the conventional group (CNV), the impression was made using the open-tray splint impression technique. An electronic and optical 3D measuring instrument was used to scan the standard model and the conventional plaster model to obtain STL files. Using 3D data processing software (GOM Inspect Pro, Zeiss), the distance and angle between the abutments in the CNV impression and the PG impression were measured and compared with the data from the standard model.

Results: The distance deviation in the PG and the CNV was 145 ± 196 μm and 96 ± 150 μm, respectively, with a significant difference (P < 0.001). The angle deviation in the PG and the CNV was 0.82 ± 0.88° and 0.74 ± 0.62°, respectively, with no significant difference (P = 0.267). In the PG, the distance deviation was negatively correlated with the distance between implants (r = -0.145, P = 0.028) and positively correlated with the angle of implants (r = 0.205, P = 0.002). The angle deviation was negatively correlated with the distance between implants (r = -0.198, P = 0.003) and positively correlated with the angle of implants (r = 0.172, P = 0.009). In the CNV, the effect of inter-implant distance on impression accuracy was also shown by Spearman correlation analysis: r = 0.347 (P < 0.001) for distance deviation and r = -0.012 (P = 0.859) for angle deviation. The effect of inter-implant angulation on impression accuracy deviation was r = -0.026 (P = 0.698) for distance deviation and r = 0.056 (P = 0.399) for angle deviation.

Conclusions: The CNV method is closer to the real value of the original model. The distance between implants and the distribution angle had a weak correlation with the accuracy of digital impressions but no significant correlation with the accuracy of traditional impressions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11443943PMC
http://dx.doi.org/10.1186/s12903-024-04888-1DOI Listing

Publication Analysis

Top Keywords

accuracy implant
12
edentulous jaws
12
digital impressions
8
impressions stereophotogrammetry
8
stereophotogrammetry edentulous
8
cnv impression
8
impression
6
implant abutment
4
abutment level
4
level digital
4

Similar Publications

[TiRobot-assisted minimally invasive treatment of coracoid process fractures of scapula].

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi

January 2025

Department of Orthopedic Trauma, Beijing Jishuitan Hospital, Beijing, 100035, P. R. China.

Objective: To explore effectiveness of TiRobot-assisted screw implantation in the treatment of coracoid process fractures of the scapula.

Methods: A retrospective analysis was conducted on the clinical data from 24 patients with coracoid process fractures of the scapula admitted between September 2019 and January 2024 and met selection criteria. Among them, 12 patients underwent TiRobot-assisted screw implantation (robot group) and 12 underwent manual screw implantation (control group) during internal fixation.

View Article and Find Full Text PDF

Can robotic arm-assisted total knee arthroplasty be applied to valgus deformity.

Arch Orthop Trauma Surg

January 2025

Department of Orthopaedic Surgery, University Hospital centre (Saint Etienne), Avenue Albert Raimond, Saint-priest-en-Jarez, 42270, France.

Introduction: Total knee arthroplasty (TKA) in valgus knees is challenging. Optimal ligament balance, implant neutral or moderate valgus alignment are crucial but conventional instrumentations usually lead to outliers. Robotic arm assisted TKA (RATKA) advantages could answer this challenge.

View Article and Find Full Text PDF

Dynamic navigation technology can "real-time guide" the implantologist to place the implant in the alveolar bone of the missing tooth area according to the preoperative design of the optimal site and path, making the whole implant surgery process more safe and precise. In order to further promote the standardized application of oral implant dynamic navigation technology, China Association of Gerontology and Geriatrics has convened distinguished experts to engage in deliberations and develop the standard. This standard covers the basic requirements, indications and contraindications, operation procedures, common complications and treatment measures, and accuracy verification.

View Article and Find Full Text PDF

Imaging Findings, Complications, and Mimics after Common and Advanced Dental Procedures.

Radiographics

February 2025

From the Department of Radiology, Nihon University School of Dentistry at Matsudo, 2-870-1 Sakaecho-Nishi, Matsudo, Chiba 271-8587, Japan (K.I., K.O., T.K.); Department of Diagnostic Radiology, National Cancer Center Hospital East, Chiba, Japan (H.K.); Department of Radiology, VA Boston Health Care System, Boston, Mass (V.C.A.A.); and Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Mass (O.S.).

Various new dental treatment methods have been introduced in dental clinics, and many new materials have been used in recent years for dental treatments. Dentistry is divided into several specialties, each offering unique treatments, such as endodontics, implantology, oral surgery, and orthodontics. CT and MR images after dental treatment reveal a variety of hard- and soft-tissue changes and dental materials, which often cause image artifacts.

View Article and Find Full Text PDF

Objectives: The advent of O-arm navigation optimized the oblique lumbar interbody fusion (OLIF) procedure, allowing the operator to simultaneously perform OLIF and percutaneous posterior pedicle screw implantation without patient position change, thus improving the fluency and accuracy of the OLIF procedure (called as OLIF360). Nevertheless, a consensus regarding its suitability for patients with severe spinal stenosis remains elusive. This study aims to investigate the clinical efficacy of OLIF360 and its imaging changes in severe lumbar spinal stenosis cases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!