Access to and use of glycemic data are central to optimal management of diabetes. Use of continuous glucose monitoring (CGM) data to guide the management of diabetes has increased dramatically thanks to improved ease of use, accuracy, and availability. Retrospective CGM data collected throughout the day and night allow clinicians to visualize glycemic patterns, and single-page summary views like the Ambulatory Glucose Profile (AGP) Report make rapid interpretation both feasible and intuitive. A systematic approach that integrates retrospective CGM-generated data at clinic visits and other clinical interactions with personal use of CGM data can optimize glycemic management.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3949/ccjm.91a.23090 | DOI Listing |
J Diabetes Sci Technol
January 2025
Unit of Endocrine Diseases and Diabetology, Department of Medicine, ASST Papa Giovanni XXIII, Bergamo, Italy.
Aims: According to the 2023 International Consensus, glucose metrics derived from two-week-long continuous glucose monitoring (CGM) can be extrapolated up to 90 days before. However, no studies have focused on adults with type 1 diabetes (T1D) on multiple daily injections (MDIs) and with second-generation intermittently scanned CGM (isCGM) sensors in a real-world setting.
Methods: This real-world, retrospective study included 539 90-day isCGM data from 367 adults with T1D on MDI therapy.
Front Physiol
December 2024
College of Sports Science, Jishou University, Jishou, China.
Purpose: To examine the effects of structured aerobic exercise on 24-hour mean blood glucose outcomes assessed by continuous glucose monitors in adults with type 2 diabetes.
Methods: The study established specific inclusion and exclusion criteria and conducted a comprehensive search across five databases, including PubMed, Web of Science, Embase, Cochrane Library, and EBSCOhost from the start year of each database's coverage to 22 July 2024. The quality of the included studies was evaluated using the Cochrane Handbook 5.
Diabetes Technol Ther
January 2025
Department of Pediatrics, Motol University Hospital and 2 Faculty of Medicine, Prague, Czechia.
The recommended threshold for the time spent on continuous glucose monitoring (CGM) is established at 70%. However, glucose outcomes in children with type 1 diabetes (CwD) using CGM for a different proportion of time within this threshold have not been evaluated yet. The study aims to compare glycemic parameters among CwD who spent 70%-89% and ≥90% on CGM using the population-wide data from the Czech national pediatric diabetes registry ČENDA.
View Article and Find Full Text PDFActa Diabetol
January 2025
Department of Materno-Fetal Medicine, Genetics and Reproduction, Institute of Biomedicine of Seville (IBIS), Hospital Universitario Virgen del Rocio/CSIC/University of Seville, Avda. Manuel Siurot s/n. ES, Seville, 41013, Spain.
Aims: This study aims to evaluate the impact of continuous glucose monitoring (CGM) on pregnancy outcomes in women with pregestational diabetes mellitus (PGDM).
Methods: A retrospective cohort study was conducted on 387 pregnant women with PGDM at Virgen del Rocío University Hospital in Seville, spanning from 2016 to 2022. The patients were categorized into two groups: 212 women who used continuous glucose monitoring (CGM) and 175 women who self-monitoring of blood glucose (SMBG).
Am J Clin Nutr
January 2025
Laboratory of Biological Modeling, National Institute of Diabetes and Digestive and Kidney Diseases, NIH, Bethesda, MD, United States. Electronic address:
Background: Continuous glucose monitors (CGMs) are used to characterize postprandial glucose responses and provide personalized dietary advice to minimize glucose excursions. The efficacy of such advice depends on reliable glucose responses.
Objectives: To explore within-subject variability of CGM responses to duplicate presented meals in an inpatient setting.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!