Greener analysis of eleven basic drugs in blood and urine using carbowax 20M based biofluid sampler (BFS) device.

J Chromatogr B Analyt Technol Biomed Life Sci

Institute of Forensic Science & Criminology, Panjab University, Chandigarh 160014, India. Electronic address:

Published: October 2024

AI Article Synopsis

  • * The BFS allows for the collection of biological samples without dilution or pre-treatment, with analytes successfully back-extracted for analysis using gas chromatography-mass spectrometry (GC-MS).
  • * The method demonstrated good precision and recovery rates, making it suitable for forensic toxicology applications, while also being evaluated for its environmentally friendly characteristics.

Article Abstract

For the first time, a novel biofluid sampler (BFS) and sample preparation device is applied for the analysis of 11 basic drugs (i.e., pheniramine, chlorpheniramine, fluoxetine, tramadol, amitriptyline, ketamine, diazepam, chlordiazepoxide, clozapine, chlorpromazine, dothiepin) in biological matrices (i.e., blood and urine). BFS utilizes advanced, highly effective sorbents derived from sol-gel sorbent coating technology onto cellulose fabric substrate, improving sample collection and retention. BFS has the capability to retain a biological sample from 10 to 1000 µL without requiring any dilution or pre-treatment of the sample. The biological samples were pipetted onto the BFS device and dried at room temperature. Subsequently, adsorbed analytes were back-extracted into 1000 µL of methanol without requiring any imposed external diffusion process and then analyzed by gas chromatography-mass spectrometry (GC-MS). A one-factor-at-a-time (OFAT) screening procedure was used to extensively screen and optimize several parameters, including sample volume, elution time, solvent volume, and solvent type. Under the optimal conditions of the study, the method was found to be linear within the range 0.1-10 µg mL for both blood and urine. Quantification limits were established for blood samples within the range of 0.072-0.095 μg mL and for urine samples within the range of 0.050-0.069 μg mL. The precisions within and between days were less than 7% and 10%, respectively. The target analytes showed good recoveries utilizing the recommended protocol, with ranges of 45.1%-103.4%. Furthermore, the methodology has been effectively implemented in forensic toxicology case work. Moreover, the green characteristics and applicability of the suggested methodology was evaluated using softwares i.e., AGREE and BAGI.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2024.124327DOI Listing

Publication Analysis

Top Keywords

blood urine
12
basic drugs
8
biofluid sampler
8
sampler bfs
8
bfs device
8
samples range
8
bfs
5
sample
5
greener analysis
4
analysis eleven
4

Similar Publications

Prospective validation study of a combined urine and plasma test for predicting high-grade prostate cancer in biopsy naïve men.

Scand J Urol

January 2025

Department of Urology, Odense University Hospital, Odense, Denmark; Academy of Geriatric Cancer Research (AgeCare), Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark.

Objective: Early and accurate diagnosis of prostate cancer (PC) is crucial for effective treatment. Diagnosing  clinically insignificant cancers can lead to overdiagnosis and overtreatment, highlighting the importance of accurately selecting patients for further evaluation based on improved risk prediction tools. Novel biomarkers offer promise for enhancing this diagnostic process.

View Article and Find Full Text PDF

Molecular recognition and detection of small bioactive molecules, like neurotransmitters, remain a challenge for chemists, whereas nature found an elegant solution in form of protein receptors. Here, we introduce a concept of a dynamic artificial receptor that synergically combines molecular recognition with dynamic imine bond formation inside a lipid nanoreactor, inducing a fluorescence response. The designed supramolecular system combines a lipophilic recognition ligand derived from a boronic acid, a fluorescent aldehyde based on push-pull styryl pyridine and a phenol-based catalyst.

View Article and Find Full Text PDF

This study evaluates the impact of acute pyelonephritis in pregnant women on the in vivo activity of renal OAT3 using the endogenous biomarker (EB) 6β-hydroxycortisol (6β-OHF) renal clearance (CL 6β-OHF) and AUC validated by correlating with the secretion clearance (CL) of the probe drug furosemide. Additionally, 6β-OHF formation clearance (CL 6β-OHF) as well as urinary (Ae/Ae) and plasma (AUC/AUC) ratios were also evaluated as EB for hepatic CYP3A activity. Pregnant women in their third trimester of gestation, diagnosed with acute pyelonephritis, were recruited before (pre-treatment, n = 8) and after (post-treatment, n = 8) cefuroxime treatment and resolution of acute pyelonephritis.

View Article and Find Full Text PDF

Background: Monocyte to high-density lipoprotein cholesterol ratio (MHR) is considered a novel marker of inflammation. However, whether MHR can predict the risk of diabetic kidney disease (DKD) remains uncertain. Our research aimed to investigate the relationship between MHR and DKD.

View Article and Find Full Text PDF

Background: The aim of this study is to evaluate the efficacy and safety of diacylglycerol (DAG) edible oil intervention in patients with chronic metabolic syndrome complicated by asymptomatic hyperuricemia through a multicenter, prospective, double-blind, randomized controlled clinical trial.

Methods: A multicenter, double-blind, and randomized controlled trial involving 176 patients was designed. All patients with chronic metabolic syndrome complicated by asymptomatic hyperuricemia who meet inclusion and exclusion criteria will be included in the study and will be randomized to either group A or group B.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!