A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Microcirculatory Dysfunction in Patients With Diabetes Mellitus Detected by a Distributed System of Wearable Laser Doppler Flowmetry Analysers. | LitMetric

The paper is devoted to the study of perfusion and amplitude-frequency spectra of laser Doppler flowmetry (LDF) signals in patients with diabetes mellitus (DM) in different skin areas of the upper and lower extremities using a distributed system of wearable LDF analysers. LDF measurements were performed in the areas of the fingers, toes, wrists and shins. The mean perfusion values, the amplitudes of blood flow oscillations in endothelial, neurogenic, myogenic, respiratory and cardiac frequency ranges, and the values of nutritive blood flow were analysed. The results revealed a decrease in tissue perfusion and nutritive blood flow in the lower extremities and an increase in these parameters in the upper extremities in patients with DM. A decrease in the amplitudes of endothelial and neurogenic oscillations was observed. The obtained results confirm the possibility of using wearable LDF analysers to detect differences in the blood flow regulation in normal and pathological conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbio.202400297DOI Listing

Publication Analysis

Top Keywords

blood flow
16
patients diabetes
8
diabetes mellitus
8
distributed system
8
system wearable
8
laser doppler
8
doppler flowmetry
8
lower extremities
8
wearable ldf
8
ldf analysers
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!