Background: Rigorous antibiotic stewardship is advised by international societies to combat rising antibiotic resistance. A major component of these programs is the metric used for antibiotic consumption measurement. A method for standardized antimicrobial administration ratio (SAAR) is suggested by the Centre for Disease Control & Prevention-National Healthcare Safety Network (NHSN).
Objectives: We applied the SAAR method to calculate antibiotic consumption in a tertiary care hospital in India. We also validated a limited sampling approach to calculate SAAR.
Method: The prospective study was conducted in three medical intensive care units over a period of 12 months. Monthly antibiotic consumption was measured by the hospital electronic records. Limited sampling was performed by weekly bedside review of the antibiotic orders. Formulae for SAAR calculation were derived from the NHSN guide. SAAR obtained by electronic records and limited sampling were compared to validate this approach.
Results: SAAR was calculated as >1 for an Indian hospital (1.49 by electronic records and 1.43 by limited sampling approach). The difference between the two ratios was not statistically significant ( = .47).
Conclusions: SAAR in our setting is 1.49, which is slightly higher than the NHSN benchmark. Antibiotic usage (AU) risk adjustment based on data from the NHSN might not be adequate for calculating SAAR for Indian hospitals. There is a need to perform AU risk factor analysis for Indian settings for better defining SAAR in Indian context. The limited sampling approach can be adapted for calculation of SAAR in settings with limited resources.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11440567 | PMC |
http://dx.doi.org/10.1017/ash.2024.396 | DOI Listing |
Anal Chem
January 2025
Environment Research Institute, Shandong University, Qingdao 266237, China.
Globally, drug-impaired driving fatalities now exceed those from drunk driving, urging the need for on-site and roadside detection methods. In this study, a photothermal desorption and reagent-assisted low-temperature plasma ionization miniature ion trap mass spectrometer (PDRA-LTP-ITMS) was developed for on-site detection of drug-impaired driving. The pseudomultiple reaction monitoring (MRM) in PDRA-LTP-ITMS enables continuous ion selection during ion introduction and improved sensitivity to nearly 3-fold compared with the conventional full scan mode.
View Article and Find Full Text PDFJMIR Form Res
January 2025
CIRCLE - Complex Intervention Research in Health and Care, Department of Women's and Children's Health, Uppsala University, Uppsala, Sweden.
Background: Parents of children treated for cancer may experience psychological difficulties including depression, anxiety, and posttraumatic stress. Digital interventions, such as internet-administered cognitive behavioral therapy, offer an accessible and flexible means to support parents. However, engagement with and adherence to digital interventions remain a significant challenge, potentially limiting efficacy.
View Article and Find Full Text PDFThyroid
January 2025
Division of Endocrinology, Diabetes and Metabolism, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
In the era of molecular testing, thyroid nodules with indeterminate cytology are increasingly being managed nonoperatively. The false-negative rates of these molecular tests, and therefore missed malignancies, are not well defined in real-world clinical practice. This retrospective study of patients undergoing fine needle aspiration (FNA) biopsy at our health system between November 2017 and March 2022 included nodules with The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC) III and IV cytology and negative, currently negative, or negative but limited ThyroSeq version 3 (TSv3) results.
View Article and Find Full Text PDFActa Bioeng Biomech
June 2024
1School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, China.
: Brain tissue immersed in cerebrospinal fluid often exhibits complex mechanical behaviour, especially the nonlinear stress- strain and rate-dependent responses. Despite extensive research into its material properties, the impact of solution environments on the mechanical behaviour of brain tissue remains limited. This knowledge gap affects the biofidelity of head modelling.
View Article and Find Full Text PDFAnal Chem
January 2025
Department of Bioengineering, University of Washington, SeattleWashington98195, United States.
Cell-to-cell heterogeneity in lipid signaling underlies variations in response and recurrence for many cancers, including leukemias. A highly parallel, miniaturized thin-layer chromatographic platform capable of assaying single cells was developed. Ultrasmall volumes (50 pL) of standard fluorescent lipids were separated with excellent repeatability, reproducibility, and limits of detection.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!