This study aims to develop methods to design the complete magnetic system for a truly portable MRI scanner for neurological and musculoskeletal (MSK) applications, optimized for field homogeneity, field of view (FoV), and gradient performance compared to existing low-weight configurations. We explore optimal elliptic-bore Halbach configurations based on discrete arrays of permanent magnets. In this way, we seek to improve the field homogeneity and remove constraints to the extent of the gradient coils typical of Halbach magnets. Specifically, we have optimized a tightly packed distribution of magnetic NdFeB cubes with differential evolution algorithms and a second array of shimming magnets with interior point and differential evolution methods. We have also designed and constructed an elliptical set of gradient coils that extend over the whole magnet length, maximizing the distance between the lobe centers. These are optimized with a target field method minimizing a cost function that considers also heat dissipation. We have employed the new toolbox to build the main magnet and gradient modules for a portable MRI scanner designed for point-of-care and residential use. The elliptical Halbach bore has semi-axes of 10 and 14& cm, and the magnet generates a field of 87& mT homogeneous down to 5700& ppm (parts per million) in a 20-cm diameter FoV; it weighs 216& kg and has a width of 65& cm and a height of 72& cm. Gradient efficiencies go up to around 0.8& mT/m/A, for a maximum of 12& mT/m within 0.5& ms with 15& A and 15& V amplifier. The distance between lobes is 28& cm, significantly increased with respect to other Halbach-based scanners. Heat dissipation is around 25& W at maximum power, and gradient deviations from linearity are below 20% in a 20-cm sphere. Elliptic-bore Halbach magnets enhance the ergonomicity and field distribution of low-cost portable MRI scanners, while allowing for full-length gradient support to increase the FoV. This geometry can be potentially adapted for a prospective low-cost whole-body technology.

Download full-text PDF

Source
http://dx.doi.org/10.1002/nbm.5258DOI Listing

Publication Analysis

Top Keywords

portable mri
12
elliptical halbach
8
gradient
8
magnet gradient
8
gradient modules
8
mri scanner
8
field homogeneity
8
elliptic-bore halbach
8
gradient coils
8
halbach magnets
8

Similar Publications

Age-related atrophy of the human hippocampus and the enthorinal cortex starts accelerating at around age 60. Due to the contributions of these regions to many cognitive functions seamlessly used in everyday life, this can heavily impact the lives of elderly people. The hippocampus is not a unitary structure, and mechanisms of its age-related decline appear to differentially affect its subfields.

View Article and Find Full Text PDF

Purpose: Integrated MRI and linear accelerator systems (MR-Linacs) provide superior soft tissue contrast, and the capability of adapting radiotherapy plans to changes in daily anatomy. In this dataset, serial MRIs of the abdomen of patients undergoing radiotherapy were collected and the luminal gastro-intestinal tract was segmented to support an online segmentation algorithm competition. This dataset may be further utilized by radiation oncologists, medical physicists, and data scientists to further improve auto segmentation algorithms.

View Article and Find Full Text PDF

Neuroimaging is a cornerstone in the diagnosis and treatment decision-making for brain acute ischemic stroke. A rapid and accurate diagnosis is the key, specifically for time-critical reperfusion therapies. Successful reperfusion of salvageable penumbra can reduce the extent of ischemic stroke and thus improve clinical outcomes, whereas reperfusion of irreversibly affected brain tissue is thought to be futile and may result in harm due to the risk of hemorrhagic transformation.

View Article and Find Full Text PDF

SlipChip Enables the Integration of CRISPR-Cas12a and RPA for Fast and Stand-Alone HPV Detection.

Anal Chem

December 2024

State Key Laboratory of Magnetic Resonance and Atomic Molecular Physics, Wuhan National Laboratory for Optoelectronics, National Centre for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology - Wuhan National Laboratory for Optoelectronics, Chinese Academy of Sciences, Wuhan 430071, China.

Human papillomavirus (HPV) screening is vital for the early detection and prevention of cervical cancer. However, existing methods often face challenges related to speed, simplicity, and multiplexing, especially in resource-limited settings. Here we developed a portable SlipChip-based multiplexed and rapid nucleic acid testing platform, named SMART, designed to simultaneously detect HPV16 and HPV18.

View Article and Find Full Text PDF

A method is presented for high-precision chemical detection that integrates quantum sensing with droplet microfluidics. Using nanodiamonds (ND) with fluorescent nitrogen-vacancy (NV) centers as quantum sensors, rapidly flowing microdroplets containing analyte molecules are analyzed. A noise-suppressed mode of optically detected magnetic resonance is enabled by pairing controllable flow with microwave control of NV electronic spins, to detect analyte-induced signals of a few hundredths of a percent of the ND fluorescence.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!