A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Single-Piece Implant Systems and its Longterm Stability: An Evaluative Research. | LitMetric

Objective: The objective of this research was to compare the longstanding stability of single-piece implant systems to typical two-piece systems by analyzing patient records retrospectively.

Methods: A retrospective examination of patient records from January 2010 to December 2020 was undertaken at the Department of Oral Implantology, University Hospital. The research included dental rehabilitation patients who got single- or two-piece implant systems. Patient demographics, implant features, surgical procedures, and follow-up results were extracted. Implant success rates, stability defined by resonance frequency analysis (RFA) utilizing Osstell ISQ®, and peri-implant bone loss evaluated by standardized periapical radiographs at baseline and follow-up visits were the main outcomes.

Results: The research involved 320 patients (160 per cohort). The average patient age was 52.7 years, with 55% men. The mandibular region received 65% of implants, and the maxillary region the rest. Single-piece cohort A had 94.6% implant success, and two-piece cohort B 96.2%. Implant success rates were similar between cohorts ( = 0.412). The mean ISQ scores were 72.4 ± 4.8 in cohort A and 74.8 ± 5.1 in cohort B ( = 0.086). Peri-implant bone loss was 1.8 ± 0.7 mm in cohort A and 1.4 ± 0.6 mm in cohort B ( = 0.031).

Conclusion: Single-piece implant systems provide a stable and successful alternative to classic two-piece systems. However, patient selection, surgical technique, and monitoring are essential to reduce peri-implant problems and improve clinical results. To improve implant dentistry patient care and evidence-based clinical practice, single-piece and two-piece implant systems' design, biomechanical features, and longstanding performance should be studied.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11426815PMC
http://dx.doi.org/10.4103/jpbs.jpbs_399_24DOI Listing

Publication Analysis

Top Keywords

implant systems
16
single-piece implant
12
implant success
12
implant
9
two-piece systems
8
patient records
8
two-piece implant
8
systems patient
8
success rates
8
peri-implant bone
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!