Transcatheter aortic valve replacement (TAVR) is frequently associated with stroke due to debris embolization. Although the risk of stroke with newer-generation devices is lower, stroke still represents a significant cause of mortality and morbidity post-TAVR. The Sentinel cerebral embolic protection device (CEPD) is a dual-embolic filter device designed to capture debris dislodged during TAVR. A systematic literature search was performed on the major bibliographic databases to retrieve studies that compared TAVR with and without Sentinel CEPD. Pooled odds ratios (ORs) with 95% confidence intervals (CIs) were calculated using the DerSimonian-Laird random-effects model, with a P value of <0.05 considered statistically significant. This meta-analysis included 6 studies with 25,130 patients undergoing TAVR (12,608: Sentinel CEPD; 12,522: without Sentinel CEPD). The use of the Sentinel CEPD in TAVR was associated with a statistically significant lower risk of acute kidney injury (OR: 0.89; 95% CI: 0.81-0.97; P = 0.01]. The use of Sentinel CEPD in TAVR was associated with a statistically insignificant trend toward a reduction in stroke (OR: 0.80; 95% CI: 0.58-1.10; P = 0.18), all-cause mortality (OR: 0.74; 95% CI: 0.51-1.07; P = 0.11), and major vascular complications (OR: 0.74; 95% CI: 0.46-1.19; P = 0.21). The use of Sentinel CEPD in patients undergoing TAVR does not lead to a statistically significant reduction in stroke, all-cause mortality, or major vascular complications; however, the risk of acute kidney injury is lower. Further randomized studies are warranted to confirm these findings.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/CRD.0000000000000797 | DOI Listing |
Alzheimers Dement
December 2024
Department of Pathology and Laboratory Medicine, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, USA.
Background: Recent studies suggest genome-wide-association-studies (GWAS) loci confer their effects on microglia in late-onset Alzheimer's disease (LOAD) brains. Relatively fewer studies have investigated the effects of other genome-wide significant loci (p<5e) using human neurons.
Method: GWAS itself cannot directly identify causal variant-(effector)gene-pairs as GWAS only reports the sentinel variant at a given locus.
Introduction: The late autumn epizootic of the highly pathogenic avian influenza virus (HPAIV) subtype H5N1 in Serbia in 2023 caused massive mortality in the migratory population of common cranes (). This is the first time HPAIV has been identified in the common crane in Serbia, leading to mass mortality of this bird species.
Methods: To understand the pathological impact of HPAIV in cranes, we evaluated the pathological changes in the tissues of common cranes.
Eur J Cancer
January 2025
University of Perugia, Unit of Medical Oncology, Santa Maria della Misericordia Hospital, Perugia, Italy.
A unique collaboration of multi-disciplinary experts from the European Association of Dermato-Oncology (EADO), the European Dermatology Forum (EDF), and the European Organization of Research and Treatment of Cancer (EORTC) was formed to make recommendations on cutaneous melanoma diagnosis and treatment, based on systematic literature reviews and the experts' experience. Cutaneous melanomas are excised with one to two-centimeter safety margins. For a correct stage classification and treatment decision, a sentinel lymph node biopsy shall be offered in patients with tumor thickness ≥ 1.
View Article and Find Full Text PDFJ Addict Med
December 2024
From the Division of Birth Defects and Infant Disorders, National Center on Birth Defects and Developmental Disabilities, CDC, Atlanta, GA (ELT, AND, KM, SMG, LG, DMM-D, SYK); Eagle Global Scientific, Atlanta, GA (ELT, AND); G2S Corporation, Shavano Park, Texas (AND); Department of Epidemiology, Emory University, Atlanta, GA (AND); Friends Research Institute, Baltimore, MD (MT); University of New Mexico Health Sciences Center, Albuquerque, NM (PMS, LL); University of Rochester, Rochester, NY (NSS, SC); University of South Florida, Tampa, FL (TW, JML); Boston Medical Center, Boston, MA (EMW, HS); University of Utah, Salt Lake City, UT (MS, JS); Center for Health Research, Kaiser Permanente Northwest, Portland, OR (MH, AD); and The Ohio State University, Columbus, OH (PDS, KR).
Background: Mixed evidence exists regarding stroke rates when comparing self-expanding valves (SEVs) to balloon-expandable valves (BEVs) in transcatheter aortic valve replacement (TAVR). This study investigates the debris captured by the SENTINEL cerebral protection system (CPS) during TAVR.
Methods: Seventy-five consecutive patients who underwent TAVR with CPS from March to December 2023 were recruited.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!