Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: The aim of this study was to evaluate the accuracy of screening tools for sarcopenia and to determine whether the same or different cutoff points should be applied in patients with chronic stroke.
Materials And Methods: Sixty-eight participants with residual hemiparetic deficit for over 6 months were enrolled. We evaluated the accuracy of calf circumference, SARC-F questionnaire, SARC-CalF, and Ishii's score chart using the Asia Working Group for Sarcopenia (AWGS) 2019 revised criteria as the gold standard.
Results: Sarcopenia was identified in 22 participants (32.4%) based on the AWGS criteria. Overall, SARC-F showed the lowest diagnostic accuracy. The Area Under the receiver operating characteristic Curves (AUC) of calf circumference, SARC-F, SARC-CalF, and Ishii's score chart were 0.77 (95% confidence interval [CI], 0.66-0.88), 0.58 (95% CI, 0.42-0.74), 0.75 (95% CI, 0.62-0.87), and 0.78 (95% CI, 0.65-0.90), respectively. The mean AUC of SARC-F was inferior to SARC-CalF (0.58 vs. 0.75, = 0.035).
Conclusions: The accuracy and diagnostic properties of calf circumference, SARC-CalF, and Ishii's score chart were comparable (mean AUC of 0.77, 0.75, and 0.78, respectively). SARC-F showed the lowest accuracy (mean AUC = 0.58). The recommended screening tools are calf circumference, SARC-CalF, and Ishii's score chart. It is not recommended to rely solely on SARC-F for screening sarcopenia after stroke. We proposed potential new cutoff points for each screening instrument, including SARC-F, SARC-CalF, calf circumference in women, and Ishii's score chart for both men and women.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/10749357.2024.2409000 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!