A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ionic Liquid-Based Hybrid Gel Microcolumns for Enhanced Narcotic Detection in Portable Micro-Gas Chromatography. | LitMetric

Ionic Liquid-Based Hybrid Gel Microcolumns for Enhanced Narcotic Detection in Portable Micro-Gas Chromatography.

ACS Appl Mater Interfaces

Department of Mechanical Engineering, Hongik University, 94 Wausan-ro, Mapo-gu, Seoul 121-791, Republic of Korea.

Published: December 2024

As the societal issue of increasing global illicit drug usage emerges, there is a growing demand for more portable and versatile drug detectors. Traditional drug analysis techniques such as gas chromatography (GC), liquid chromatography (LC), and Fourier transform infrared spectroscopy (FTIR) face significant challenges in adapting to diverse real-world applications due to their size, cost, and power requirements. While advancements have been made in the development of on-site drug detection methods such as fluorescence, stereoresonance energy transfer (FRET), colorimetric, electrochemical sensing, and lateral flow assays (LFAs), their reliance on specific reactive materials poses limitations in effectively detecting a wide range of narcotics. Therefore, this study proposes the development of specialized microcolumns with optimized stationary phases for next-generation portable microfabricated GC-based narcotic detectors. The stationary phase consists of a hybrid gel incorporating the ionic liquid, 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIM][BF]) and OV-1. The stationary phase not only enhances interactions between drug analytes but also demonstrates improved separation characteristics among various narcotic substances. Additionally, the principles of the separation results were validated through density functional theory (DFT) analysis, and the effective separation of over seven types of narcotics was demonstrated through temperature optimization. This research lays the groundwork for the advancement of next-generation portable drug analyzers, offering significant potential in the field.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.4c10094DOI Listing

Publication Analysis

Top Keywords

hybrid gel
8
next-generation portable
8
stationary phase
8
drug
6
ionic liquid-based
4
liquid-based hybrid
4
gel microcolumns
4
microcolumns enhanced
4
enhanced narcotic
4
narcotic detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!