A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Increased pulsation ratio in rear quarters reduces machine-on time and milking on empty teats. | LitMetric

Increased pulsation ratio in rear quarters reduces machine-on time and milking on empty teats.

J Dairy Sci

Veterinary Physiology, Vetsuisse Faculty, University of Bern, 3001 Bern, Switzerland. Electronic address:

Published: December 2024

Dairy cows usually store more milk in the rear quarters of the udder than the front quarters. With conventional machine milking, this leads to an earlier cessation of milk flow in front quarters than the rear quarters and hence unavoidable milking on empty front teats. We tested the hypothesis that an increased pulsation ratio in rear quarters reduces milking on empty front teats as well as machine-on time. We have also tested if the different amplitude of cyclic vacuum fluctuations during milking with simultaneous versus alternate pulsation within front and rear quarters, respectively, impacts milking characteristics. Ten Holstein dairy cows were milked twice daily at 14-h and 10-h milking intervals. The pulsation ratio in the front quarters was 65:35, but was set at 65:35, 70:30, 75:25, or 80:20 in the rear quarters. Whole udder milk flow, claw vacuum, and mouthpiece chamber vacuum of all 4 quarters were recorded during milking. Teat tissue thickness of all 4 teats was measured with a cutimeter at 5 and 30 min after cluster detachment. Total milk yield did not differ among treatments, indicating complete udder emptying. The time of quarter milk flow of the front quarters did not differ among treatments but decreased with increasing pulsation ratio in rear quarters. In addition, faster milking of the rear quarters at a higher pulsation ratio caused higher peak and average milk flow rates, a shorter duration of milk flow decline, and a reduced machine-on time. The increased milk flow at a higher pulsation ratio did not cause a significant reduction of the claw vacuum at the used sample size. Teat tissue thickness did not significantly differ among treatments, likely because milking on empty teats did almost not occur in the rear quarters, and treatment settings did not differ in the front quarters. Simultaneous pulsation caused higher amplitudes of cyclic vacuum fluctuation than alternate pulsation. However, milking characteristics did not differ between simultaneous and alternate pulsation. Overall, an increased pulsation ratio in rear quarters reduces machine-on time, increases milking performance, and reduces the time of milking on empty teats in front quarters, without an increased impact on teat tissue thickness.

Download full-text PDF

Source
http://dx.doi.org/10.3168/jds.2024-25257DOI Listing

Publication Analysis

Top Keywords

rear quarters
40
pulsation ratio
28
front quarters
24
milk flow
24
milking empty
20
quarters
17
ratio rear
16
machine-on time
16
milking
13
increased pulsation
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!