Alternative Surgical Treatment Method for 5th Metacarpal Neck Fractures: Comparison of Clinical Outcomes of Intramedullary and Transverse K-Wire Fixations with Additional Antirotational K-Wire.

Acta Chir Orthop Traumatol Cech

Bahçeşehir University Medical School, Department of Orthopedics and Traumatology, VM Medicalpark Pendik Hospital, Department of Orthopedics and Traumatology, İstanbul, Turkey.

Published: September 2024

Purpose Of The Study: The purpose of this study was to assess the clinical outcomes and complications associated with intramedullary and transverse K-wire fixations of 5th metacarpal neck fractures.

Material And Methods: Patients who were operated for 5th metacarpal neck fractures between 2019 and 2022 were evaluated retrospectively. Regarding the surgical treatment methods, patients were assessed by dividing them into two groups. The first group comprised patients who underwent treatment with an intramedullary K-wire. The second group comprises patients who underwent transverse K-wire fixation.

Results: The average quick DASH score of all patients was 5.6±4.7 in the intramedullary K-wire fixation group and 5.9±5.1 in the transverse K-wire fixation group. An average 5th finger metacarpophalangeal joint extension limitation was 6.2±5.7° in the intramedullary fixation group and 6.1±5.8° in the transverse K-wire group. The mean radiological union time was 4.9±0.7 weeks in the intramedullary fixation group and 5.1±0.7 weeks in the transverse K-wire group. No statistically significant difference was found between the quick DASH scores and degrees of the MCP joint extension limitation ( p=0.785). Intramedullary fixation and transverse K-wire fixations are effective surgical treatment methods for metacarpal neck fractures.

Discussion: It has been reported that the intramedullary fixation method in metacarpal bone fractures is more effective than the fixation methods with cross and transverse K-wire. But our results revealed no difference in clinical outcomes between the two surgical fixation methods.

Conclusions: We observed no statistically significant difference between the two fixation techniques with regard to union, clinical outcomes, or complications.

Key Words: intramedullary fixation; metacarpal neck fracture; transverse K-wire fixation.

Download full-text PDF

Source
http://dx.doi.org/10.55095/ACHOT2024/030DOI Listing

Publication Analysis

Top Keywords

transverse k-wire
36
metacarpal neck
20
intramedullary fixation
20
clinical outcomes
16
fixation group
16
surgical treatment
12
5th metacarpal
12
k-wire
12
k-wire fixations
12
k-wire fixation
12

Similar Publications

Background: Kirschner wire (K-wire) and intramedullary (IM) screw fixation are accepted techniques for treatment of unstable proximal phalanx fractures, but comparative reports are lacking. This study aimed to evaluate early clinical outcomes following treatment with K-wire or IM fixation.

Methods: A retrospective review of all proximal phalanx fractures treated surgically at a single center by multiple surgeons was performed from May 1, 2019 to March 1, 2024.

View Article and Find Full Text PDF

Background: Pediatric supracondylar humeral fractures present considerable surgical challenges due to the difficulty of achieving proper fracture alignment and stable fixation while avoiding injury to the ulnar nerve. This study assesses the biomechanical performance of a novel Kirschner wire (K-wire) fixation device (KFD), designed to enhance stability and reduce complications linked to traditional K-wire configurations.

Methods: Using finite element analysis (FEA), we evaluated four fixation strategies for treatment of pediatric supracondylar humeral simple transverse fractures: crossed pin fixation, crossed pin fixation with KFD, two lateral pin fixation, and two lateral pin fixation with KFD, under various mechanical loads.

View Article and Find Full Text PDF

Temporary Circular External Fixation for Spanning the Traumatized Ankle Joint.

JBJS Essent Surg Tech

December 2024

Division of Orthopaedic Surgery, Department of Surgical Sciences, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa.

Background: Temporary ankle-spanning circular fixation aims to provide osseous stability while (1) allowing access to and recovery of the traumatized soft-tissue envelope and (2) facilitating safe, comfortable, and clinically relevant cross-sectional imaging for surgical planning. It is most commonly utilized in a "span-scan-plan" treatment strategy in cases of peri-articular fractures around the ankle. Conventional monolateral fixators are prone to morbidity at the half-pin sites in the foot and variation in construct stability.

View Article and Find Full Text PDF

Background: The use of patient-specific instruments (PSIs) for osteotomies is becoming more popular in orthopaedic surgery for correcting mechanical axis and posttraumatic deformities. However, the PSI reduction guides have great potential for intraoperative deformation, which adversely affects the accuracy of the procedure.

Purpose: To conduct a finite element analysis (FEA) to analyze different design parameters to improve the intraoperative stability of the reduction guides.

View Article and Find Full Text PDF

Introduction: K wire is one of the most common implants used for fixation of acromioclavicular joint dislocation. The migration of K wire from the AC joint to the spinal canal is a rare occurrence. In this report, the authors present a case of a young adult who presented with weakness of the left upper limb secondary to migration of the K wire from the AC joint to the spinal canal.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!