Background: Obstetric anesthesia guidelines are essential for standardizing obstetric anesthesia practices globally and ensuring high-quality patient care. However, practices may vary across different settings, and there are limited data from Arab countries. This study aims to gain insights into obstetric anesthesia practices in several major hospitals across Arab countries.

Methods: A questionnaire was emailed to 85 obstetric anesthesiologists/anesthesia chairpersons in major hospitals, including academic medical institutions and central hospitals, across 11/22 Arab countries. This survey gathered data on key structural and process-related obstetric anesthesia indicators.

Results: Out of 85 contacted, we had 56 responses (65.8%), with 41 being fully completed, providing insights into obstetric anesthesia indicators. Regarding structure: 31 (76%) hospitals had an operating room adjacent to the delivery room, all had intensive care units, and 22 (54%) had a lead obstetric anesthesiologist. For equipment, 19 (46%) had a video laryngoscope in the delivery suite, and 20 (49%) occasionally used ultrasound for epidurals. Regarding process: 33 (81%) held regular meetings, and 21 (51%) conducted research. Before epidural and spinal procedures, 26 (63%) and 28 (68%) required coagulation studies for patients without a history of hemorrhagic complications, while 38 (93%) and 36 (88%) mandated a platelet count, respectively. For labor analgesia, 34 (83%) primarily used epidurals, and 15 (37%) placed preemptive catheters in high-risk pregnancies. For cesarean delivery, 40 (98%) used spinals, with 16 (39%) using intrathecal morphine and 22 (54%) administering aspiration prophylaxis before general anesthesia. Regarding spinal-induced hypotension, 6 (15%) used prophylactic phenylephrine infusion.

Conclusion: This survey highlights variations in obstetric anesthesia practices among various major hospitals in several Arab countries, compared to international recommendations. It emphasizes the need for obstetric anesthesia registries in the Arab world for future research. Further studies are required to outline country-specific practices, improve resource allocation, and enhance obstetric population safety and satisfaction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11437647PMC
http://dx.doi.org/10.1186/s12871-024-02728-xDOI Listing

Publication Analysis

Top Keywords

obstetric anesthesia
32
anesthesia practices
16
arab countries
16
insights obstetric
12
major hospitals
12
obstetric
10
anesthesia
9
practices major
8
hospitals arab
8
practices
6

Similar Publications

Introduction Effective postoperative analgesia following lower segment cesarean section (LSCS) is crucial for promoting surgical recovery and fostering maternal-neonatal bonding. This study aimed to compare the efficacy of two IV dexamethasone doses (8 mg and 4 mg) in managing postoperative pain in LSCS patients. The objective was to assess whether the 4 mg dose provides comparable pain relief to the 8 mg dose, with the goal of identifying the optimal dosage for effective pain management with minimal side effects.

View Article and Find Full Text PDF

Background: Rapid onset of epidural analgesia is an important concern for the parturient. Commonly, the local anaesthetic mixture is administered through the epidural catheter. Drugs administered through the epidural needle might decrease the onset time and enhance the spread of medication within the epidural space.

View Article and Find Full Text PDF

ESAIC focused guidelines for the management of the failing epidural during labour epidural analgesia.

Eur J Anaesthesiol

February 2025

From the Servicio de Anestesia y Reanimación, Hospital Universitario Gregorio Marañón, Calle de O'Donnell, 48, 28009 Madrid, Madrid, Spain (NB), the Servicio de Anestesia, Hospital Universitario Sanitas La Zarzuela, Madrid, c/ Pleyades, 25, 28023 Madrid, Spain (NB), the Servicio de Anestesia y Reanimación, Hospital Universitario La Paz, Madrid, P° de la Castellana, 261, 28046 Madrid, Spain (IVG), the Department of Paediatric and Obstetric Anaesthesiology, Juliane Marie Centre, Rigshospitalet & Institute of Clinical Medicine, University Hospital of Copenhagen, Copenhagen, Denmark (AA, KL), the University Hospital Würzburg, Department of Anaesthesiology, Intensive Care, Emergency and Pain Medicine, Würzburg, Germany (PK, SR), the Division of Anesthesia Critical Care and Pain, Tel Aviv Sourasky Medical Center affiliated with the Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv Israel (CFW), the London North West NHS University Trust, Watford Road, London, UK HA1 3UJ (NL), the Department of Anesthesia & Intensive Care Medicine, Liège University Hospital, Belgium (PYD), the Servicio de Anestesia y Reanimación. Hospital Universitario Fundación Jiménez Díaz. Av. de los Reyes Católicos, 2. 28040 Madrid. Spain (EGA), the Department of Anesthesiology, Perioperative Medicine and Pain Treatment, Shaare Zedek Medical Center, Hebrew University, Shmuel Beyth St 12, Jerusalem, 9103102 Israel (AI), the Department of Anesthesia and Intensive Care, Akademiska Sjukhuset, Sjukhusvägen, 75185, Uppsala, Sweden (AK), the Department of Anesthesia, Beilinson Hospital, Petach Tikvah, Israel affiliated with Tel Aviv University Medical School (SOZ), the Department of Anaesthesiology, Wilhelmina Children's Hospital, University Medical Centre Utrecht, Utrecht, the Netherlands (OvdB), the Department of Cardiovascular Sciences, KU Leuven, and Department of Anaesthesiology, UZ Leuven, Belgium (MvdV), the Department of Anaesthesia, Intensive Care and Pain Medicine, University General Hospital of Valencia, Methodology Department, European University of Valencia, Valencia, Spain (CSR).

Background: Labour epidural analgesia reportedly fails in up to 10 to 25% of cases. A joint taskforce of European Society of Anaesthesiology and Intensive Care (ESAIC) experts was created to develop this focused guideline on the management of failing epidural analgesia in a previously well functioning epidural catheter.

Design: Six clinical questions were defined using a PICO (Population/Intervention/Comparison/Outcome) strategy to conduct a systematic literature search.

View Article and Find Full Text PDF

Introduction/purpose: Nusinersen, the first treatment approved for all spinal muscular atrophy (SMA) types, is administered intrathecally through lumbar puncture. We used ultrasound assistance or a landmark-based technique to access the lumbar intrathecal space in adult SMA patients. This study aimed to evaluate the technical success and adverse events (AEs) in such patients using either technique over a long observation period.

View Article and Find Full Text PDF

Mothers encounter several challenges to sustain breastfeeding until the recommended 6 months of age. There is limited evidence on the impact of women's labor pain experiences upon cessation of breastfeeding. We aimed to investigate the association between women's labor pain experiences, intrapartum interventions, and pre-birth psychological vulnerabilities and cessation of breastfeeding.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!