Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Interest in virus-based therapeutics for the treatment of genetic and oncolytic diseases has created a demand for high-yield, low-cost virus-manufacturing processes. However, traditional analytical methods of assessing infectious virus titer require multiple processing steps and manual counting, limiting sample throughput, and increasing human error. This bottleneck severely limits the development of new manufacturing unit operations to drive down costs. In this work, we utilize an Incucyte Live-Cell Analysis System to develop a high-throughput infectious titer assay for adenovirus expressing a GFP-transgene. Although previous studies have demonstrated live-cell imaging's potential for use with other viruses, they provide little guidance regarding the selection of the viewing and analysis parameters. To fill this gap, we develop an algorithmic approach to identify the optimum viewing and analysis parameters and create a statistical workflow for quantifying infectious adenovirus in a sample dilution series in a standard 24-well microplate. The developed assay is comparable to Hexon staining, the gold-standard for adenovirus infectious titer, with a Pearson correlation coefficient of 0.9. Finally, the developed algorithmic approach and statistical workflow were applied to create an assay for adenovirus titer using a 96-well microplate, allowing five times more samples to be quantified compared to the standard 24-well plate. While this assay uses a GFP-insert that precludes its use in a clinical environment, the key learnings surrounding the careful use of viewing and analysis parameters, and the statistical workflow are widely applicable to implementing life-cell imaging for dilution-series-based assays. Moreover, this method directly enables the fast and accurate evaluation of virus samples in a preclinical environment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jbiotec.2024.09.018 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!